Divar - Easy | Installation Manual | Operating instructions
Alarm inputs
If an input causes an alarm
•
The camera causing the alarm is displayed on the full screen.
•
The alarm icon is displayed. An alarm status message is displayed.
•
The alarm beeper sounds. The alarm
•
A controllable camera might be moved to a pre-defined position.
Acknowledging an input alarm
1. Press the acknowledge key
to acknowledge the alarm.
> The beeper is silent.
> The alarm
and
indicators are no longer lit.
> The alarm status message disappears.
> The last-used view mode is restored.
The alarm icon remains visible as long as the input causing the alarm is active.
If an alarm is not acknowledged, the beeper switches off after the dwell time but
the alarm still needs to be acknowledged.
If auto-acknowledge is enabled, the beeper, and the alarm
indicators switch off after the dwell time.
Bosch Security Systems
and the
indicators flash.
and
Video loss alarm
If the loss of a video signal causes an alarm:
•
Monitor A switches to multiscreen view. The lost camera signal is displayed
as a black cameo with the video loss message. The border around the
camera with the video loss is red. An alarm status message is displayed.
•
The alarm beeper sounds.
•
The video loss
and the
indicators flash.
Acknowledging a video loss alarm
1. Press the acknowledge key
to acknowledge a video loss alarm.
> The beeper is silent.
> The video loss
and
indicators are no longer lit.
> The alarm status message disappears.
> The last-used view mode is restored.
If the camera with video loss is visible, the black cameo and the video loss
message continue to be displayed as long as there is no video present.
If an alarm is not acknowledged, the beeper, and the video loss
indicators switch off after the dwell time but the alarm still needs to be
acknowledged.
If auto-acknowledge is enabled, the beeper, and the video loss
indicators switch off after the dwell time.
Multiple alarms
Monitor A switches to multiscreen view if more than one alarm occurs. The
latest alarm status message is always shown. Pressing the acknowledge key
deactivates all alarms.
EN | 3-11
and
and