Siemens VIS3I-328 Installation Manual page 52

Integrated system unit
Table of Contents

Advertisement

Unit
Connector Name
Master or standalone
Serial Port 1
PCCON Port 2
Serial Port 3
Serial Port 4
Test/Config Port 9
Keyboard Port 10
Option card ports 12 & 13
Slave
Serial Port 16
PCCON Port 17
Serial Port 18
Serial Port 19
Option cards ports 20 & 21
Camera 1
+
-
GND
+
-
GND
Camera 17
52
Siemens Building Technologies
Fire Safety & Security Products
Interface
RS-232/422
RS-232
RS-232/422
RS-232/422
RS-232
RS-422/485
RS-232
RS-232/422
RS-232
RS-232/422
RS-232/422
RS-232
Serial port loopback connectors (2)
Tab. 40
D-type telemetry external loopback connectors
These self-test external loopback tests confirm that the D-type telemetry ports are
working correctly. To conduct this test, you need to link the D-type ports for
cameras 1–16 to the ports for cameras 17–32. You do this by linking the two
removable screw terminal blocks with pairs of link wires, as shown below for the
first block of four cameras. (This pattern should be repeated for the remaining three
blocks.)
Camera 2
+
-
GND
+
-
GND
Camera 18
Fig. 16
Self-test – Camera D-type port linking
Video routing
VisiPC includes a powerful test to automatically check the routing of video signals
from all the camera inputs to all the monitor outputs, including the expansion
connection between units.
Before running this test, you should connect all available sources of clean video to
the camera inputs. This test is therefore best conducted once installation is
complete.
To run the test:
1.
Select the VisiPC Self-Test Tab.
2.
Select the Test Type to Video Routing from the Run Tests button.
3.
Press the Send button.
Loopback type for
first test
RS-232 Male
RS-232 Female
RS-232 Male
RS-232 Male
(None – connected to VisiPC)
RS-422
RS-232 TTL
RS-232 Male
RS-232 Female
RS-232 Male
RS-232 Male
RS-232 TTL (at either card connector)
Camera 3
+
-
GND
+
-
GND
Camera 19
Loopback type for
second test
RS-422
RS-422
RS-422
RS-422
RS-422
RS-422
Camera 4
+
-
GND
+
-
GND
Camera 20