Connecting To The Power; Power Supply Connection Example - Yamaha RCX240 User Manual

4-axis robot controller
Hide thumbs Also See for RCX240:
Table of Contents

Advertisement

4. Connecting to the power

Attach the power connector to the power cable and insert it into the "AC IN" connector on
the front panel of the controller as shown below.
4.1

Power supply connection example

Connection example
See 4.5.
Single phase
AC 200V
Leakage
breaker
c
CAUTION
Do not make incorrect terminal connections. Incorrect connections may cause
malfunction.
See 4.8.
Noise
filter
Surge
absorber
See 4.9.
4. Connecting to the power
See 4.6.
See 4.7.
Circuit
Electro-
protector
magnetic
contactor
Circuit
protector
Chapter 3 INSTALLATION
1
2
RCX240
3
L
N
4
L1
N1
5
6
7
8
9
10
3-7