Connect to CD-CP00-US Ethernet socket using a crossover cable or via a hub. Set
the IP address of your NIC card within the range of the SV8100 CD-CP00-US. The
default IP address of the CD-CP00-US is 192.168.0.10 (Sub Net Mask =
255.255.255.0)
Using a terminal application (e.g. Hyperterminal), set the connection to TCP/Winsock.
The Host IP address is set by Program 10-12-01 on the SV8100. The default is
192.168.0.10 as shown below. The default port number is 5963.
3 - 2
The SV8100 CD-CP00-US can slow down when the DIM
is running on a busy SV8100 system. This is unavoidable,
as the CD-CP00-US must process all system activity and
output the corresponding information to the DIM.