ELEC
IGNITION SYSTEM
CHARGE COIL
1. Measure:
S Charge coil resistance
Out of specification ! Replace.
Charge coil resistance:
Brown/White
(Br/W) – Black (B)
497.7
(68 _F)
PULSER COIL
1. Measure:
S Pulser coil resistance
Out of specification ! Replace.
Pulser coil resistance:
White/Red (W/R) – Black (B)
12.6
(68 _F)
THERMO SWITCH
1. Measure
S Thermo switch continuity
Out of specification ! Replace.
Thermo switch continuity
temperature:
Pink (P) – Black (B)
a 66 X 74 _C
(100.4
b 57 X 43 _C (93.2 X 78.8 _F)
1 Discontinuity
2 Continuity
3 Discontinuity
Measurement steps:
S Suspend thermostat in a vessel.
S Place known reliable thermometer in water.
S Heat water slowly.
S Observe thermometer, while stirring water
continually.
44
608.3 Ω at 20 _C
X
15,4 Ω at 20 _C
X
125.6 _F)
X
A Temperature
B Time