Replacement
1. Removing the pinch limiter assembly
Remove the pinch limiter assembly.
(Refer to Section 6-4.)
2. Disconnecting the connectors
Disconnect the harness from the connector
(CN20) on the DR-428BG board with tweezers.
3. Replacing the pinch solenoid
assembly
(1) Remove the two precision screws with the
pinch slider assembly drawn into the arrow
direction and lift off the pinch solenoid
assembly.
(2) Align two holes in a new pinch solenoid
assembly with the two positioning pins on the
MD chassis respectively.
(3) Reattach the pinch solenoid utilizing the two
precision screws with the pinch slider
assembly drawn in the arrow direction.
Tightening Torque : 0.1 N.m {1 kgf.cm}
4. Reconnecting the connector
Reconnect the harness to the connector (CN20)
on the DR-428BG board with tweezers.
5. Reattaching the pinch limiter
assembly
Reattach the pinch limiter assembly.
(Refer to Section 6-4.)
Adjustment after Replacement
6. Checking the tape path adjustment
(Refer to Section 7-4.)
HVR-1500
Precision screws
P1.4 x 3.5
Pinch slider assembly
Pinch solenoid assembly
Harness
Positioning pins
CN20
DR-428BG board
6-17