• Replacement service controls must be programmed to
meet the range configuration they are being used in. Fail-
ure to do so will result in an F-code (F1 - E3).
Program Procedure
Press the following keypad sequence after the unit has been
powered up.
Convection Freestanding/Slide In:
- Convection Broil
- Clean
- Baked Goods
- Stop Time
- #1, #9, #0
- Timer Set
- Start
- Cancel
Non-Convection Freestanding/Slide In:
- Clean
- Stop Time
- #0
- Oven Light
- #1
- Start
- Cancel
This will set the board for the proper range configuration.
NOTE: These program sequences also check all the capacitive
glass touchpad keys. If the sequence does not work, unplug
the unit, wait 10-seconds, plug the unit back in, and rerun the
sequence from the "PF" mode.