Error Codes - KitchenAid KESS300B Reference Manual

Electronic range controls “b” & “d” line wall ovens
Hide thumbs Also See for KESS300B:
Table of Contents

Advertisement

The microcomputer contains self-diagnostic codes that will be dis-
played on the control panel whenever a failure occurs when using the
range. Audible 1-second and 5-second tones will sound to alert the user
whenever a failure code is being displayed. Each code can be cancelled
by pressing the CANCEL/OFF keypad. The code will return if the user
attempts to use the range before the failure has been corrected.
The F/E-Codes will be displayed for the indicated reasons, shown in the
following chart.
FAULT
ERROR
F1
E0
F1
E1
F1
E3
F1
E4
F1
E9
F2
E0
F2
E2
F2
E3
F2
E4
F3
E0
F3
E1
F3
E2
F4
E1
F5
E1
F5
E3
F5
E5
F5
E6
F5
E7
F6
E0
F7
E0
PF

Error Codes

FAULT
FAULT CONSTANT
PRIORITY
NAME IN SOFTWARE
N/A
FAULT EEPROM
EEPROM CHECKSUM
N/A
ERROR
CONFIG JUMPERS NO
7
MATCH
2
Q8 SHORTED
0
STACK OVERFLOW
CANCEL KEY TOO
4
LOW
CANCEL KEY
3
CHANNEL
5
KEY DOWN TOO LONG
6
KEYS UNSETTLED
9
OPEN PLAT
8
SHORTED PLAT
10
OVEN TEMP TOO HIGH OVEN TEMP TOO HIGH (RUNAWAY)
SHORTED MEAT
15
PROBE
SELF-CLEAN LATCH
13
WILL NOT MAKE
LOSS OF GND L1 N
1
REVERSE
SELF CLEAN TEMP
14
NOT SATISFIED
DOOR OPEN AND
16
LOCKED
DOOR WILL NOT
17
UNLATCH
12
AMBIENT OVER TEMP
11
INPUT SWITCH ERROR
FAULT
DESCRIPTION
EEPROM READ FAULT (SILENT FAULT, NOT
DISPLAYED)
EEPROM CHECKSUM DOES NOT MATCH AT START
KEY (SILENT FAULT, NOT DISPLAYED)
CONFIGURATION JUMPER CHANGE, FREESTAND,
ELECTRIC SWITCHES ,OR P9 (PIN 6 TO 7) CHANGED
SINCE POWER UP
Q8 SHORTED
STACK OVERFLOW, HIGHEST PRIORITY
CANCEL KEY LEVEL TOO LOW (OPEN)
CANCEL KEY LOOP TEST FAILED
KEY HELD DOWN TOO LONG OR KEYBOARD SHORT
KEYS UNSETTLED PROBABLY DUE TO NOISE
PLAT SENSOR OPEN
PLAT SENSOR SHORTED
HEAT PROBE SHORTED (LESS THAN 1500 OHMS)
SELF-CLEAN LATCH WILL NOT MAKE AFTER
30-SECONDS
LOSS OF 120 VAC ACROSS L1 TO GROUND, OR Q19
CIRCUIT ERROR
SELF-CLEAN TEMPERATURE NOT SATISFIED AFTER
30-MINUTES
DOOR LOCKED WITH DOOR OPEN
DOOR UNLOCKED AND WILL NOT UNLATCH
AMBIENT SENSOR OPENED (TOO HOT)
INPUT SWITCHES WILL NOT FOLLOW THEIR STROBE
LEVEL (SHORTED TO GROUND)
POWER FAILURE (NOT A FAILURE OF CONTROL.
PRESS CANCEL)
- 29 -
SERVICE
ACTION
SUSPECT CONTROL
SUSPECT CONTROL
SUSPECT CONTROL
SUSPECT CONTROL
SUSPECT CONTROL
SUSPECT KEYPAD
ASSEMBLY
SUSPECT KEYPAD
ASSEMBLY
SUSPECT KEYPAD
ASSEMBLY
SUSPECT KEYPAD
ASSEMBLY
SUSPECT KEYPAD
ASSEMBLY
SUSPECT TEMP
SENSOR
SUSPECT TEMP
SENSOR
SUSPECT TEMP
SENSOR
SUSPECT MEAT
PROBE
SUSPECT INPUT
SWITCH
SUSPECT INPUT
SWITCH
SUSPECT INPUT
SWITCH
SUSPECT INPUT
SWITCH
F6
F7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents