Host Channel Led Link Rate Indications - Dell PowerVault MD3860f Owner's Manual

Storage arrays
Hide thumbs Also See for PowerVault MD3860f:
Table of Contents

Advertisement

Item
Indicator, Button, or
Connector
4
USB port
5
Mini USB port
6
Password reset switch
7
SAS expansion port (2)
8
16 Gbps FC IN port (4)
9
Seven segment display
sequence
10
System identification
indicator
11
Controller fault
indicator
12
Controller power
indicator
13
Cache active or cache
offload indicator
14
Battery fault indicator

Host Channel LED Link Rate Indications

Above each FC port is a pair of LED indicators. The status of any FC port can be determined by applying
the condition of each LED pair.
Table 1. LED Status Indicators
LED 0
Off
On
Off
On
16
Icon
Description
Reserved port.
Dell support only.
Pressing this switch resets the password.
Provides SAS OUT connection for cabling to a daisy
chained expansion enclosure. Port 0 expansion port is
recommended.
Provides host-to-controller SAS connection.
Displays status or error codes for the storage array.
The system identification indicator blinks blue when
system identification switch push-button on the
enclosure front panel is pressed.
The controller fault indicator lights amber when controller
fault is detected.
The controller power indicator lights green when
controller power is on.
The cache active or cache offload indicator lights green
when on-board controller memory contains data.
If AC power fails, this LED changes to indicate cache
offload status.
If the password reset function has successfully changed
the password, this LED flashes on and off briefly.
The battery fault indicator lights amber when battery
backup unit or battery has failed.
LED 1
Off
Off
On
On
Port Status
Link down
4 Gbps link
8 Gbps link
16 Gbps link

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3460

Table of Contents