Mitsubishi Electric PFFY-P20VKM-E Installation Manual

Air-conditioners for building application indoor unit
Hide thumbs Also See for PFFY-P20VKM-E:

Advertisement

Air-Conditioners For Building Application
INDOOR UNIT
PFFY - P

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο, καθώς και το εγχειρίδιο εγκατάστασης
της εξωτερικής μονάδας, πριν από την εγκατάσταση της μονάδας κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dış ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
VKM-E (2)
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Ελληνικά (GR)
Português (P)
Türkçe (TR)
Русский (RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PFFY-P20VKM-E

  • Page 1: Installation Manual

    Air-Conditioners For Building Application INDOOR UNIT PFFY - P VKM-E (2) • INSTALLATION MANUAL FOR INSTALLER English (GB) For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch (D) Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    Failure to observe these instructions may result in overheating or a fire. • When installing or relocating, or servicing the outdoor unit, use only the • Use only accessories authorized by Mitsubishi Electric and ask the dealer specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it or an authorized technician to install them.
  • Page 3: Installing The Indoor Unit

    3. Installing the indoor unit (mm) 3.1. Indoor unit mounting bracket installation • Install the bracket firmly to the wall structure (stud, etc.). (Fig. 3-1) • Use a level to install the mounting bracket horizontally. • Install the indoor unit 150 mm or below from the floor. Indoor unit mounting bracket Note: To prevent the indoor unit mounting bracket from vibrating slightly, be sure...
  • Page 4: Refrigerant Pipe

    3. Installing the indoor unit (mm) 2) For right downward or left downward piping (Fig. 3-8) (The following figure is a view of the bottom of the indoor unit from above.) When the unit is installed on the wall. When the unit is installed on the floor. Fig.
  • Page 5: Drainage Piping Work

    • If the indoor unit is installed in a high location such as a high-rise apartment, strong winds may cause the drain water to flow back through the drain hose and leak from the unit. If necessary, contact your nearest Mitsubishi Electric repre- sentative for the optional parts to prevent this problem.
  • Page 6: Embedding The Indoor Unit In A Wall

    5. Drainage piping work • Insert the drain hose all the way to the base of the drain pan. (Fig. 5-4) Make sure that the drain hose is securely caught on the projection in the hole in the drain pan. Fig.
  • Page 7: Electrical Work

    7. Electrical work 7.1. Indoor unit (Fig. 7-1) Remove the electrical cover. • Remove 1 screw holding the electrical cover, then move the cover. • Remove 1 screw holding the cord clamp, then move the clamp. Connect the power line, control line from the outdoor unit, and remote control lines.
  • Page 8: Test Run

    7. Electrical work 7.5. Setting addresses (Fig. 7-4) (Be sure to operate with the main power turned OFF.) 220V 240V • There are 2 types of rotary switch setting available: setting addresses 1 to 9 and CN43 over 10, and setting branch numbers. 1 How to set addresses Example: If Address is “3”, remain SW12 (for over 10) at “0”, and match SW11 (for 1 to 9) with “3”.
  • Page 9: Air Outlet Selection

    8. Test run Display (Horiz.) Swing Actual • The lower air outlet damper automatically opens and closes according to the piping temperature, intake air temperature, and operation time. The airflow direction cannot be set. 9. Air outlet selection With this function, air comes out simultaneously from the upper and lower air outlets so that the room can be cooled or heated effectively.
  • Page 10 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • Electromagnetic Compatibility Directive EU regulations: 2004/108/EC • Machinery Directive 2006/42/EC •...

Table of Contents