2. Procedure for determinin g defective expansio n valve
Checker
5.6K 5.6K 5.6K 5.6K
6
5
3
2
4
Connector
J.S.T. XNIRP-06V-A-S
Terminal
SXNI-001T-P0.6
3. Dio de bridge check method
Turn off the power and let the inverter electrolytic capacitor (C9, C10) discharge completely. Then use a tester and check continuity.
When using a digital tester, the (+) and (-) tester lead wires in the table must be reversed.
4. Inverter electrolytic capacitor (C9, C10) check method
Turn off the power, let the inverter electrolytic capacitor (C9, C10) discharge completely, and remove the capacitor from the control printed circuit
board (PWB). First, check the case for cracks, deformation and other damages. Then, using a needle-type tester, check continuity.
The tester needle should move on the scale and slowly returns to the original position. The tester needle should move
in the same way when polarities are reversed. (When measurement is taken with the polarities reversed, the tester
needle exceeds the scale range. Therefore, let the capacitor discharge before measurement.)
LED
(red)
Replace control PWB.
1
4 5
Deter minat ion of norm al co nditi on
Measure resistance in expansion valve coil.
Normal resistance between red
terminal of expansion valve
lead wire and white or orange
terminal,gray terminal of
expansion valve lead wire and
yellow or blue terminal :
about 46 (at 20
Insert checker shown at left into
connector (CN12) on control PWB, and
operate air conditioner.
Do LEDs on checker light in orderly
NO
sequence
(lighting of 1 LED => lighting of 2 LEDs)
If frost accumulates on 2-way valve after 10 to 20
minutes of cooling operation, then thermistors with
yellow and black lead wires may be defective. Check
these thermistors.
Replace thermistor assembly.
Needle-type tester
Normal resistance value
B
Value in ( ) is for digital tester.
3-9
)
YES
YES
Thermistors in
normal condition
Defective thermistor
(several M )
AY-ZP35PR
NO
Replace expansion
valve assembly.