AY-ZP35PR
Problem
Outdoor
symptom
unit indi-
cation
(LED1)
Indoor and
13-time
outdoor units
do not oper-
ate.
Indoor and
outdoor units
operate.
Indoor and
14-time
outdoor units
do not oper-
ate.
Indoor unit
Malfunc-
tion No.
Lamp
Main Sub
Timer (Orange)
13
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
3
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
14
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Content of diagnosis
Main
Sub
DC com-
Compressor
pressor
startup error
Compressor
rotation error.
(at 120o energiz-
ing)
Compressor
rotation error
(at 180o energiz-
ing)
Detection error of
inverter current.
Outdoor unit
PAM over volt-
PAM
age error
PAM clock error
PAM under volt-
age error
3-20
Check point
(1) Check the colors
(1) Correct the instal-
(red, white, orange)
lation. (U: Red, V:
of the compressor
White, W: Orange)
cords for proper con-
nection. (PWB side,
compressor side)
(2) Check if the IPM ter-
(2) Replace the out-
minal resistance val-
door unit control
ues are uniform.
PWB assembly.
(3) Check if outdoor
(3) Replace the out-
main relay (MRY1)
door unit control
turns on and voltage
PWB assembly.
of both end of the
condenser (C10) has
become DC290-
330V.
(4) No abnormality
(4) Replace the com-
found in above
pressor.
inspections (1)
through (3).
(1) Check the circuit of
(1) Replace the out-
detection of inverter
door unit control
current.
PWB assembly.
(1) Check the AC power
(1) Correct the instal-
supply voltage for
lation.
fluctuation.
(2) No abnormality
(2) Replace the PWB
found in above
assembly.
inspection.
(1) Check the PAM
(1) Replace the out-
clock for proper
door unit control
input.
PWB assembly.
(1) Check the AC power
(1) Correct the instal-
supply voltage for
lation.
fluctuation.
(2) No abnormality
(2) Replace the PWB
found in above
assembly.
inspection.