Installation - Kenwood KHG 601 Instructions For Use Manual

Built-in cooking hobs
Hide thumbs Also See for KHG 601:
Table of Contents

Advertisement

4 - INSTALLATION

TECHNICAL INFORMATION FOR THE
INSTALLER
In order to install the cooker top into the
kitchen fixture, a hole with the dimensions
shown in fig. 4.2 has to be made, bearing in
mind the following:
If the cooktop is not installed directly
above an oven and/or if its base is
accessible through a cupboard or
drawer
space
thermal protection barrier must be
installed below the base of the cooktop
as indicated in fig.4.3.

The thermal protection barrier must be:
removable with the use of a tool for
installation and service;
heat-resistant;
made from low thermal conductivity
material.
A 30 mm ventilation gap must be
provided between
the bottom of the
appliance
any
cabinetry,
draw unit, thermal
protection barrier
or appliance.
If the cooktop is
installed
above
an
oven,
oven shall have
a
cooling
motor; the two
appliances shall
be connected to the gas and/or electrical
supply with independent connections.
The hob must be kept no less than 200
mm away from any side wall (fig. 4.2).
The hob must be installed at least 60 mm
from the wall (fig. 4.2).
There must be a distance of at least
650 mm between the hob and any wall
cupboard or extractor hood positioned
immediately above (see fig. 4.1).
14
after
installation,
and
the
Fig. 4.2
fan
a
Fig. 4.1
Clearance
Space for
connections
Fig. 4.3
Thermal
protection
barrier
Door

Hide quick links:

Advertisement

Table of Contents
loading