TABLE FOR THE CHOICE OF THE INJECTORS
GB IE
Cat:
BURNERS
Auxiliary (A)
Semirapid (SR)
Rapid (R)
Triple Ring (TR)
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semirapid (SR)
Rapid (R)
Triple Ring (TR)
LUBRICATION OF THE GAS TAPS
The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of
the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
II
2H 3+
Nominal
Reduced
Power
Power
[kW]
[kW]
1,00
0,40
1,75
0,45
3,00
0,75
3,50
1,50
LPG
G30/G31
28-30/37 mbar
Ø injector
[1/100 mm]
50
66
87
93
Air necessary for combustion [m
2,00
3,50
6,00
7,00
Natural Gas
G20
20 mbar
Ø injector
[1/100 mm]
77
101
129
135
/h x kW)
3
/h]
3
21