Reconditioning the Linear Imager Scanner Battery
To maintain optimal performance of the linear imager scanner NiMH battery, perform a battery recondition
approximately once a year.
To begin the battery recondition cycle:
Scan Battery Recondition below.
1.
Place the linear imager scanner into the cradle.
2.
NOTE If the scanner is removed from the cradle during the battery reconditioning cycle, the scanner exits the
battery reconditioning mode of operation and returns to the normal mode of battery charging (see
Charging the Linear Imager Scanner Battery on page
re-scan the Battery Recondition parameter and place the scanner in the cradle.
The linear imager scanner must perform two charge cycles to complete the battery reconditioning process
3.
(discharge/charge/discharge/charge). See
Battery Reconditioning LED Definitions
Battery Reconditioning LED Definitions
Table 1-4
Battery Reconditioning
Mode
Discharging
Charging
Reconditioning Complete
Note: When the scanner is inserted into the CR0078-S (standard) cradle, the scanner's LED is used as
the charging indicator.
When the scanner is inserted into the CR0078-P (presentation) cradle, the cradle's LED is used
as the charging indicator.
Battery Recondition
LED
Red Flash
Green Flash
Green - Solid (always on)
1-12). To restart the battery reconditioning cycle,
Table
1-4.
Comments
Time to discharge is approximately 2.5 hours.
Time to charge is typically 3 hours with an external
power supply.
The linear imager scanner enters a trickle charge until
the linear imager scanner is removed from the cradle.
GETTING STARTED 1 - 13