Operating Instructions
Normal Operating Sounds
Certain sounds may be made when air conditioner runs,
especialJy in a cooling mode. Sounds may include:
• Water splashing onto condenser; caused by slinger
ring attached to condenser fan. Slinger ring picks up
water (condensate) in base pan and sprays it on
condenser to increase efficiency of unit.
• Compressorcycles
frequently. High efficiency
compressors used in new Kenmora Room
AirConditionersrun more frequently but for shorter
periods and consume less energy than older, less
efficientcompressors.
• Airflowfrom air discharge vent. If sound is distracting,
try adjusting louvers on discharge vent, moving objects
that may be obstructing airflow, or reducing fan speed.
Care and Maintenance
I
WARNING
]
To avoid death or personal injury due to electrical
shock, turn off fan control and unplug power cord
before cleaning or performing maintenance on this
device.
Maintenance
Schedule
Kenmore Room Air Conditioners are designed and
manufactured to provide years of dependable service
when propedy cared for and maintained.
Maintenance Schedule (below) shows maintenance
required to keep unit operating at peak efficiency. Most
maintenance can be performed using common tools,
equipment, and products. See Maintenance Procedures
(beginning on page 24).
Large maintenance tasks, such as washing condenser
and evaporator coils, should performed by an authorized
Sears servicer (at owner's expense). Call 1-800-4-88-
1222 for location of a local authorized Sears Service
Center.
Maintenance
Required
Inspect/clean air filler.
Table 2. Maintenance Schedule
Procedure
Remove air filler and inspect. Clean if required; replace.
NOTE: Never operate air conditioner with filler removed.
Inspect air discharge louvers, return air grille, and electronic
control for dust and dirt accumulation. Clean, if necessary.
NOTE: Inspect more often in dusty environments.
Inspect louvers on outer case and remove any obstructions.
Frequency
Weekly
Inspect/clean air discharge
Weekly
louvers, retum air grille, and
electronic control.
Inspect louvers on outer case
Monthly
for obstructions.
Inspect condenser coil.
Inspect condenser coil for dirt, bent fins, and other
Annually
obstructions. Clean/repair, if necessary.
! NOTE: Inspect mare often in dusty environments.
Inspect evaporator coil.
Inspect evaporator coil for dirt, bent fins, and other
Annually
obstructions. Clean/repair, if necessary.
NOTE: nspect more often in dusty environments.
I
Inspect outer case for
I Inspect interior and exterior of outer case for scratches,
Annually
signs of damage,
paint blisters, rust, and other damage. Repair as necessary.
NOTE: Inspect more often in salty or other corrosive
environments.
Inspect/clean base pan.
Inspect base pan for scratches, blisters, rust, dents, and other
Annually
damage. Repair as necessary. Clean condensate drain
passages of any accumulated material.
NOTE: In areas of excessive humidity, use algicide (algae
inhibitor) in base pan to help reduce algae build-up.