Toshiba RAV-SM564CT-E Installation Manual
Toshiba RAV-SM564CT-E Installation Manual

Toshiba RAV-SM564CT-E Installation Manual

Air conditioner split type indoor unit
Hide thumbs Also See for RAV-SM564CT-E:

Advertisement

AIR CONDITIONER (SPLIT TYPE)

Installation Manual

Indoor Unit
Model name:
Ceiling Type
RAV-SM564CT-E
RAV-SM804CT-E
RAV-SM1104CT-E
RAV-SM1404CT-E
English
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM564CT-E

  • Page 1: Installation Manual

    AIR CONDITIONER (SPLIT TYPE) Installation Manual Indoor Unit Model name: Ceiling Type RAV-SM564CT-E RAV-SM804CT-E RAV-SM1104CT-E RAV-SM1404CT-E English Installation Manual...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3: Warning Indications On The Air Conditioner Unit

    Installation Manual Installation Manual Ceiling Type Ceiling Type Warning indications on the air conditioner unit Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’ work clothing. Warning indication Description In addition to such normal protective gear, wear the protective gear described below when undertaking the special work detailed in the table below.
  • Page 4: Precautions For Safety

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 3 – Precautions for Safety • Carry out the specified installation work to guard against the possibility of high winds and earthquake. If the air conditioner is not installed appropriately, a unit may topple over or fall down, causing an accident. •...
  • Page 5: Accessory Parts

    Installation Manual Installation Manual Ceiling Type Ceiling Type Accessory Parts Relocation • Only a qualified installer(*1) or qualified service person(*1) is allowed to relocate the air conditioner. It is dangerous for the air conditioner to be relocated by an unqualified individual since a fire, electric shocks, injury, water leakage, noise and / or vibration may result.
  • Page 6: Selection Of Installation Place

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 5 – Selection of Installation Place Installation space (Unit: mm) Reserve sufficient space required for installation or service work. Avoid installing in the following places. Select a location for the indoor unit where the cool or warm air will circulate evenly. Avoid installation in the following kinds of locations.
  • Page 7: Installation

    Installation Manual Installation Manual Ceiling Type Ceiling Type Installation Installation of hanging bolt Installation of hanging bolt Use M10 hanging bolts (4 pcs, to be local procure). • Consider the piping / wiring after the unit is hung to Matching to the existing structure, set pitch according determine the location of the indoor unit installation CAUTION to size in the unit external view as shown below.
  • Page 8: Installation Of Indoor Unit

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 7 – Before installation Draw-out direction of pipe / Installation of indoor unit In case of taking pipe from left side Taking pipe from left side is applied only to the wire drain pipe.
  • Page 9: Drain Piping

    Installation Manual Installation Manual Ceiling Type Ceiling Type Drain Piping <There is no ceiling material> Installation of remote controller (Sold separately) Hanging bolt (Procured locally) CAUTION Washer For installation of the remote controller, follow the (Procured locally) Installation Manual attached with the remote controller. Indoor Following the Installation Manual, perform the drain piping work so that water is properly drained.
  • Page 10 Installation Manual Installation Manual Ceiling Type Ceiling Type – 9 – Connection of drain hose Heat insulating process • Insert the attached drain hose into the drain pipe connecting port on the drain pan up to the end. • Using the attached drain hose heat insulator, lap the connecting section and the drain hose without clearance, and then tighten with two handing band so that heat insulator does not open.
  • Page 11: Refrigerant Piping

    Installation Manual Installation Manual Ceiling Type Ceiling Type Refrigerant Piping Evacuation * In case of flaring for R410A with the conventional flare tool, pull it out approx. 0.5 mm more than that for R22 to adjust to the specified flare size. The Perform vacuuming from the charge port of valve of the Projection margin in flaring: B (Unit: mm) copper pipe gauge is useful for adjusting projection...
  • Page 12: Electrical Connection

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 11 – Electrical Connection Heat insulation process Apply heat insulation for the pipes separately at liquid side and gas side. WARNING • For the heat insulation to the pipes at gas side, use the material with heat-resisting temperature 120 °C •...
  • Page 13: Remote Controller Wiring

    Installation Manual Installation Manual Ceiling Type Ceiling Type Wiring between indoor unit and outdoor unit Wire connection Indoor / Outdoor connecting Remote controller terminal block terminal block Figure below shows the wiring connections between the indoor and outdoor units and between REQUIREMENT the indoor units and remote controller.
  • Page 14: Applicable Controls

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 13 – Applicable Controls Installing indoor unit on high Each time button is pushed, indoor unit numbers in the control group change ceiling cyclically. Select the indoor unit to change Basic procedure for changing REQUIREMENT settings for.
  • Page 15: Power Saving Mode

    Installation Manual Installation Manual Ceiling Type Ceiling Type To secure better effect of Group control Adjust the power save setting by pushing Pushing (left side of the button), TIME buttons. select an indoor unit to be monitored. The heating sensor temperatures of indoor units and Each push of the button changes the power level Simultaneous twin, triple or double twin by 1 % within the range from 100 % to 50 %.
  • Page 16 Installation Manual Installation Manual Ceiling Type Ceiling Type – 15 – Group control for system of multiple units [Procedure example] One remote controller can control maximum 8 indoor units as a group. Manual address setup procedure 1) Specify CODE No. [12] with TEMP. While the operation stops, change the setup.
  • Page 17 Installation Manual Installation Manual Ceiling Type Ceiling Type 8 °C operation (SDI series 4 After check of the changed contents, push Push buttons simultaneously for button. 4 seconds or more. 1) Specify CODE No. [14] TEMP. and DI series 4 only) (Setup is determined.) After a while, the display part flashes and the buttons.
  • Page 18: Test Run

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 17 – Test Run Wireless remote controller Overview of test run operations using the wireless remote controller Always select HIGH] air volume. Cooling test run: Before test run Push button. 2, 3, ON / OFF →...
  • Page 19: Maintenance

    Installation Manual Installation Manual Ceiling Type Ceiling Type Maintenance ▼ Periodic Maintenance 8 hours or more daily, clean the indoor unit and • For environmental conservation, it is strongly outdoor unit at least once every 3 months. Ask a recommended that the indoor and outdoor units of professional for this cleaning / maintenance work.
  • Page 20: Troubleshooting

    Installation Manual Installation Manual Ceiling Type Ceiling Type – 19 – Troubleshooting Error codes and parts to be checked Wired Wireless remote controller remote Confirmation and check Confirmation of error log Sensor block display of controller receiving unit Judging display Main defective parts Parts to be checked / error description conditioner...
  • Page 21 Installation Manual Installation Manual Ceiling Type Ceiling Type Wired Wired Wireless remote controller Wireless remote controller remote remote Sensor block display of Sensor block display of controller controller receiving unit receiving unit Judging Judging display display Main defective parts Parts to be checked / error description conditioner Main defective parts Parts to be checked / error description...

This manual is also suitable for:

Rav-sm804ct-eRav-sm1104ct-eRav-sm1404ct-e