Download Print this page

Toshiba e-STUDIO163 Service Handbook page 116

Hide thumbs Also See for e-STUDIO163:

Advertisement

[B] Connection for developer bias adjustment
Front cover opening/closing switch
Ground to the
machine frame
( green cable )
( - ) terminal:
Connect with the white cable
[C] Connection for main charger adjustment
Front cover opening/closing switch
Ground to the
machine frame
( green cable )
( - ) terminal:
Connect with the white cable
e-STUDIO163/166/203/206
ADJUSTMENT
Fig. 3-19
Fig. 3-20
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
3 - 34
( + ) terminal:
Connect with the black cable
( + ) terminal:
Connect with the
red cable ( thick line )