Download Print this page

Toshiba e-STUDIO163 Service Handbook page 79

Hide thumbs Also See for e-STUDIO163:

Advertisement

Items
Pressure roller
Fuser roller separation finger
Feed roller
(Drawer)
Feed roller
(PFU)
Separation roller
(Bypass unit)
Feed roller
(Bypass unit)
Pickup roller
(Bypass unit)
Recovery blade
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
PM management setting <Procedure 4>
*Indicated in 8 digits
1250-0, 1, 3, 4, 6, 7
1268-0, 1, 3, 4, 6, 7
1298-0, 1
1300-0, 1
1316-0, 1
1324-0, 1
1332-0, 1
1336-0, 1, 3, 4, 6, 7
2 - 59
06/05
Remarks
<Default values of code 1250
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
<Default values of code 1268
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000
<Default values of code 1298
(e-STUDIO 163/203)>
Sub-codes 0: 0/0
Sub-code 1: 80,000/80,000
<Default values of code 1300
(e-STUDIO 163/203)>
Sub-codes 0: 0/0
Sub-code 1: 80,000/80,000
<Default values of code 1316
(e-STUDIO 163/203)>
Sub-codes 0: 0/0
Sub-code 1: 80,000/80,000
<Default values of code 1324
(e-STUDIO 163/203>
Sub-codes 0: 0/0
Sub-code 1: 80,000/80,000
<Default values of code 1332
(e-STUDIO 163/203)>
Sub-codes 0: 0/0
Sub-code 1: 80,000/80,000
<Default values of code 1336
(e-STUDIO 163/203)>
Sub-codes 0, 3, 6, 7: 0/0
Sub-code 1: 72,000/90,000
Sub-code 4: 180,000/180,000