Kenwood FM Transceiver TK-481 Service Manual page 38

800mhz/900mhz fm transceiver
Hide thumbs Also See for FM Transceiver TK-481:
Table of Contents

Advertisement

Item
Condition
9. DQT BAL
1) SYS – GRP : 4 –
adjustment
Select BAL
in tuning mode.
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
10. MAX DEV
1) SYS – GRP : 4 –
adjustment
Select MAX
in tuning mode.
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L MAX
H MAX
PTT : ON
11. T/A MAX
1) SYS – GRP : 4 –
DEV
Select TMAX
adjustment
in tuning mode.
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L TMAX
H TMAX
PTT : ON
12. NPSPAC
1) SYS – GRP : 10 –
MAX DEV
Select NMAX
adjustment
in tuning mode.
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L NMAX
H NMAX
PTT : ON
13. MIC
1) SYS – GRP : 4 – 1
sensitivity
AG : 1kHz/15mV (TK-480)
check
AG : 1kHz/8mV (TK-481)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
14. T/A MIC
1) SYS – GRP : 4 – 1
sensitivity
TA mode : ON
check
(Press [A] key, then [C] key)
AG : 1kHz/15mV (TK-480)
AG : 1kHz/8mV (TK-481)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
equipment
Power meter Panel
Deviation
meter
Oscilloscope
AG
AF VTVM
C MAX
C TMAX
C NMAX
Adjustment
Terminal
Unit
Parts
ANT
Panel
Encoder Make the demodu-
knob
lation waves into
square waves.
Universal
TK-480 : 3.8kHz
TK-481 : 1.75kHz
(According to the
larger +, –.)
TK-480 : 2.9kHz
(According to the
larger +, –.)
Check
TK-480/481
Specifications/Remarks
Method
50Hz
50Hz
TK-480 : 2.2~3.6kHz
TK-481 : 0.6~1.0kHz
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-480

Table of Contents