TK-480/481
Item
Condition
15. QT DEV
1) SYS – GRP : 4 –
adjustment
MIC input : OFF
Select FQT
in tuning mode.
Deviation meter filter setting
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750 s
PTT : ON
16. DQT DEV
1) SYS – GRP : 4 –
adjustment
Select FDQT
in tuning mode.
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
17.LTR DEV
1) SYS – GRP : 4 –
adjustment
Select FLTR
in tuning mode.
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
18. DTMF DEV 1) SYS – GRP : 4 –
adjustment
Select DTMF
in tuning mode.
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
19. MSK DEV
1) SYS – GRP : 4 –
adjustment
Select FMSK
in tuning mode.
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
20. TONE DEV 1) SYS – GRP : 4 –
adjustment
Select TONE
in tuning mode.
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
21. BATT
1) SYS – GRP : 4 –
detection
Select BATT
writing
in tuning mode.
PTT : ON
38
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Panel
Deviation
meter
Oscilloscope
AG
AF VTVM
Adjustment
Parts
Method
Encoder TK-480 : 0.75kHz
knob
TK-481 : 0.45kHz
TK-480 : 1.00kHz
TK-481 : 0.75kHz
TK-480 : 3.00kHz
TK-481 : 1.50kHz
2.5kHz
After pressing the
BATT terminal voltage : 6.2V
PTT switch, confirm
that one predeter-
mined numeric in
the range 1 to 256
appears and then
press [B] key.
That numeric will be
stored in memory.
Specifications/Remarks
0.05kHz
0.10kHz : TK-480
0.05kHz : TK-481
0.15kHz : TK-480
0.10kHz : TK-481
0.1kHz