Sanyo PLC-XP200L Service Manual page 57

Multimedia projector
Hide thumbs Also See for PLC-XP200L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No. Item
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3,4 Manual Voltage
6
Fan5 Manual Voltage
7
Fan6 Manual Voltage
8
Fan7 Manual Voltage
9
Fan8 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
253
Fan Temp Error Setting
5
Temp A Warning (Normal)
6
Temp B Warning (Normal)
7
Temp C Warning (Normal)
8
Temp B-A Warning (Normal)
9
Temp C-A Warning (Normal)
10
Temp A Warning (Eco)
11
Temp B Warning (Eco)
12
Temp C Warning (Eco)
13
Temp B-A Warning (Eco)
14
Temp C-A Warning (Eco)
15
Temp A Warning Offset (Temp)
16
Temp B Warning Offset (Temp)
17
Temp C Warning Offset (Temp)
18
Temp B-A Warning Offset (Temp)
19
Temp C-A Warning Offset (Temp)
20
Temp A Warning Offset (Time)
21
Temp B Warning Offset (Time)
22
Temp C Warning Offset (Time)
23
Temp B-A Warning Offset (Time)
24
Temp C-A Warning Offset (Time)
254
Fan Control Range Setting
16
Normal Fan Control Min Temp
17
Normal Fan Control Max Temp
18
Normal Fan1 Min
19
Normal Fan1 Max
20
Normal Fan2 Min
21
Normal Fan2 Max
22
Normal Fan3,4 Min
23
Normal Fan3,4 Max
24
Normal Fan5 Min
25
Normal Fan5 Max
26
Normal Fan6 Min
27
Normal Fan6 Max
28
Normal Fan7 Min
29
Normal Fan7 Max
30
Normal Fan8 Min
31
Normal Fan8 Max
32
Eco Fan Control Min Temp
33
Eco Fan Control Max Temp
Function
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
(Memorized)
Temp A (Room) to judge the Temp Error at Normal
Temp B (Lamp) to judge the Temp Error at Normal
Temp C (Panel) to judge the Temp Error at Normal
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
Temp A (Room) to judge the Temp Error at Eco
Temp B (Lamp) to judge the Temp Error at Eco
Temp C (Panel) to judge the Temp Error at Eco
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
Temp Warning Offset (Temp)
Time Warning Offset (Time)
(Temp/Spinning)
Temp Sensor Control Start/End Temp St Normal
Fan Spinning Set at Normal (Min/Max) (0.1V)
Temp Sensor Control Start/End Temp St Eco
Range
0-6
0-1
0-255
0-255
0-255
0-255
0-255
0-255
0-255
-
-
-
Normal
30-100
47
30-100
64
30-100
59
0-100
50
0-100
23
30-100
47
30-100
64
30-100
59
0-100
50
0-100
23
0-100
0-100
0-100
0-100
0-100
0-40
0-40
0-40
0-40
0-40
225°
Normal
20-100
31
20-100
38
0000-9990
120
0000-9990
135
0000-9990
80
0000-9990
80
0000-9990
70
0000-9990
135
0000-9990
90
0000-9990
135
0000-9990
60
0000-9990
135
0000-9990
65
0000-9990
135
0000-9990
60
0000-9990
135
20-100
31
20-100
38
-57-
Initial
Note
0
0
100
100
100
100
100
100
100
-
-
-
Ceiling
Top
Bottom
47
47
47
64
64
64
59
59
59
50
50
50
23
23
23
47
47
47
64
64
64
59
59
59
50
50
50
23
23
23
13
13
13
13
13
3
3
3
3
3
135°
45°
Top
Normal
Ceiling
Bottom
315°
Ceiling
Top
Bottom
31
31
31
38
38
38
120
120
120
135
135
135
80
80
80
80
80
80
70
70
70
135
135
135
90
90
90
135
135
135
60
60
60
135
135
135
65
65
65
135
135
135
60
60
60
135
135
135
31
31
31
38
38
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents