Bosch ICP-EZM2 Easy Series System Reference Manual page 123

Easy series
Hide thumbs Also See for ICP-EZM2 Easy Series:
Table of Contents

Advertisement

Easy Series
Programming Item
Country Code
Enclosure Tamper Enabled
Fire Bell Cut-off Time
Intrusion Bell Cut-off Time
Intrusion Abort Window
Point Alarm Verification
Entry Delay
Auto Protection Level
Latching Point and Enclosure Tamper
Latching System Device Tamper
Restrict Installer Passcode
Start Arming With Faulted Points
Passcode Length
Circuit Style
Response Time
* The middle digits = the point number. For example, "01" = Point 1, and "32" = Point 32.
Table 12.1 NF A2P Certified Configuration Values
NOTICE!
i
For supervised points (dual EOL), 2.2k Ω EOL resistors (P/N: 47819) required.
Bosch Security Systems, Inc.
Item Number
NF A2P Approved Range Section Starting Page
102
17
103
1
107
2 or 3
108
2 or 3
110
0
124
0
127
Shorter than Exit Delay
132
0
137
1
138
1
142
1
159
0
861
6
9xx2*
0
9xx5*
4 or 5
System Reference Guide
Agency Approvals and Requirements | en 123
Page 43
Page 56
Page 52
F01U087835 | 02 | 2008.10

Advertisement

Table of Contents
loading