en | System Installation and Configuration
2.4

Initial System Startup

1.
2.
Stage
Time Interval
1
0-15 sec
2
15-45 sec
3
45-75 sec
4
75 sec
Table 2.2 Initial System Startup Sequence (No wLSN devices discovered)
2.5

Perform the RFSS Site Test using the wLSN Installation Tool

The wLSN Installation Tool communicates signal strength levels, noise levels, signal-to-noise
ratio (SNR), and packet success rates. Use it to determine the best locations for wLSN device
installation.
NOTICE!
i
Before permanently installing any wLSN device, verify that the radio-frequency signal strength
(RFSS) between the planned device location and the planned wLSN Hub location is
acceptable.
CAUTION!
!
If you have wireless devices that you will not immediately install, reinsert the battery tabs or
remove the batteries to prevent battery depletion.
NOTICE!
You can perform the RFSS site test using the wLSN Hub and the specific device you wish to
i
test. However, you must use the Installation Tool with the wLSN Smoke Detector. You cannot
determine RFSS with the detector itself. Refer to Section 3.1 Perform a RFSS Site Test with the
Hub and the Device, page 28 for instructions.
F01U087835 | 02 | 2008.10
Apply AC power to the system.
Refer to Table 2.2 for the Initial System Startup sequence.
Control Center
Intermittent flashing green icon
Flashing amber circle
Single rotating amber segment
Solid green circle
System Reference Guide