Special installation (Wall embedding (vertically wall-embedding equipment))
Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts.
The fixing method marked
When the unit is fixed on a structure, select a structure of the proper thickness and height. Care
must also be taken regarding the number of fixing bolts to be used (see "3.4.1 Fixing on a structure").
<Correct>
Beams
<Reference>
After installation, measure the temperatures in the area shown in the figure below to make sure
that the values are within the specified range.
cannot be used for the unit.
Bad example of blocking exhaust
Exhaust side
(temperature of the
exhaust from FAN)
Room temperate
+ 15 °C or less
Intake side
Room temperature
+ 5 °C or less
<Incorrect>
Beams