Stratagy ES Model C1 Installation Guide
Step 3: Set Voice Board's Hardware Switches
Step 3: Set Voice Board's Hardware Switches
Important!
ProLine/2V or Dialog/4 Voice Board
1. Set Interrupt Level – Using the JP1 jumper block set the ProLine/2V or Dialog/4 interrupt
level to IRQ7.
Note
Set all ProLine/2V and Dialog/4 boards in the system to the same IRQ level.
2. Set Offset Address – Using the SW1 DIP switches 1,
2 and 3, set the offset address for the ProLine/2V
board. The default is 0000H (see table at right).
Important!
3. Verify Hookswitch State – SW1 DIP switch 4 must
be set to Off.
4. Verify that the jumper on JP7 is installed (see figures
below). If more than one ProLine/2V and Dialog/4
board is installed in the Stratagy ES, remove the
jumper on JP7 from all but one of the ProLine/2V or
Dialog/4 boards.
5. Go to
JP1
JP7
Pin position 5
(counting from
right to left)
JP7
ProLine/2V Voice Board
2
Model C1 has only one ISA slot available for a voice board (maximum port capacity
of up to four ports).
Each board in the Stratagy ES must have a
unique offset address for the system to
communicate with the board. Do NOT
duplicate offset addresses.
Step 4: Install Voice Board(s)
SW1
1 2 3 4
JP1
SW1
JP101
JP102
on
page 4
to continue the system installation procedure.
J1
J2
J3
JP7
J4
J5
JP1
3996
Dialog/4 Voice Board
Stratagy ES Model C1 Installation Guide
SW1: DIP Switches
Board
Number
1
2
1
Off
Off
(default)
2
Off
Off
3
Off
On
4
Off
On
5
On
Off
6
On
Off
7
On
On
8
On
On
1
2
3
4
O
N
SW1
JP101
SW1
JP201
JP301
J1
JP401
J2
J2
JP7
JP1
3786
Pin Position 1
(counting from right
to left)
3
Off
On
Off
On
Off
On
Off
On
12/01