TOOLS REQUIRED

• Saw
• Measuring tape
• Carpenter's square
• Large flat-blade screwdriver
• Pipe wrench

POWER SUPPLY LOCATIONS

Gas Supply:
• The pressure regulator must be connected in series with the
manifold of the cooktop and must remain in series with the
supply line regardless of the type of gas being used.
• The natural gas models are designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 7" water pressure to the
cooktop regulator.
• The liquid propane models are designed to operate at 10"
water column pressure. A regulator is required at the LP
source to provide a maximum of 14" water pressure to the
cooktop regulator.
• These gas cooktops are supplied with 1/2" NPT female gas
connection located at the left rear corner.
• A minimum 5/8" dia. metal flexible line is required.
– Use 5-foot long 5/8" flexible metal tubing. (Length must
comply with local codes.)
2"
Locate Gas Supply 2" Maximum
Protrusion From Wall or on Floor 2" From Wall

Installation Preparation

7" for 36" Models
17" for 48" Models
Gas Line
to Cooktop
16"
MATERIALS REQUIRED (not supplied)
• Pipe and fittings as required
• Manual gas line shut-off valve
• Gas pressure regulator (supplied)
• Gas-resistant pipe joint sealant
• 5 foot, 5/8" AGA-certified flexible metal gas supply line
(length must comply with local codes)
– If required by local codes, use solid pipe fittings.
NOTE: Purchase new flexible line. DO NOT USE OLD,
PREVIOUSLY USED FLEXIBLE LINE.
• For rigid connection, locate the pipe stub within area shown.
• Install a manual shut-off valve in the gas line, in an easily
accessible location.
Electric Supply:
These cooktops must be supplied with 120 volt, 60 Hz., and
connected to an individual, properly grounded branch circuit
protected by a 15 amp circuit breaker or time delay fuse.
The power cord of this appliance is equipped with a
three-prong (grounding) plug which mates with a standard
three-prong grounding wall receptacle to minimize the
possibility of shock hazard from this appliance.
If the electrical service provided does not meet the above
specifications, it is recommended that a licensed electrician
install an approved outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG FROM THE POWER CORD.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
• Locate the electric supply within the area shown or within
reach of the cooktop's six foot power cord.
• To avoid tangling cord with items stored in the cabinet, locate
the receptacle on rear wall, inside the cabinet.
Receptacle Box Cover Plate
Three Prong Plug
6
Three Prong Receptacle

Advertisement