Bosch DCN Next Generation Operation Manual page 203

Table of Contents

Advertisement

Conference System
Figure 7.10: Tx Configuration window
Bundle number
0
1 to 255
256 to 65279
Table 7.22: Bundle numbers
Bosch Security Systems B.V.
portion of this variable will be in agreement with the value of modeRateControl. Typically
the sample size will be the same for all channels in a bundle so the All Same option can be
checked to assign the same value to all channels:
SubCount: This variable can be used to limit the number of channels that will be
transmitted in the bundle. The default value is equal to 8 but can be set to any value from
0 to 8 in order to minimize bandwidth utilization when desired.
UnicastMode: This value can be used to override or modify the normal unicast versus
multicast implications of the assigned bundle number. The normal default value is Never
Multicast. The available options are:
Always Multicast: All bundles are sent multicast regardless of Bundle number.
Multicast over 1: If more than one receiver is set to receive this bundle, it will be
multicast, else it will be unicast.
Multicast over 2: If more than two receivers are set to receive this bundle, then it
will be multicast, else it will be unicast or multi‑unicast.
Multicast over 3: If more than three receivers are set to receive this bundle, then it
will be multicast, else it will be unicast or multi‑unicast.
Multicast over 4: If more than four receivers are set to receive this bundle, then it
will be multicast, else it will be unicast or multi‑unicast.
Never Multicast: Only a single bundle will be sent unicast.
MaxUnicast: This value can be set to limit the number of multi-unicast bundles sent
by this transmitter. The default for this value is 1 with allowed values of 1 through 4.
Description
Bundle not in use.
Multicast bundle
Unicast bundle