Comprising a room temperature controller (with integrated radio transmitter)
and receiver with relay outputs
Mains-independent, battery-operated room temperature controller featuring
user-friendly operation, easy-to-read display and large numbers.
Self-learning two-position controller with PID response (patented).
Operating mode selection:
- 7-day automatic mode with max. 3 heating or cooling phases.
- Continuous comfort mode.
- Continuous energy saving mode.
- Protection against frost or overheating.
- Exception day (24 hour operation) with max. 3 heating or cooling phases.
A separate temperature setpoint can be entered in automatic mode and for
the exception day for each heating or cooling phase.
Heating zone control.
Possibility to control cooling equipment.
Advantage for retrofitting, renovating, and reconstruction purposes
(completely wireless room unit).
Room temperature control in:
• Single-family and vacation homes.
• Apartments and offices.
• Individual rooms and professional office facilities.
• Commercially used spaces.
Control for the following equipment:
• Magnetic valves of an instantaneous water heater.
2
RCR10/868
REV24RF../SET
Building Technologies
206

Advertisement

Table of Contents
loading

Summary of Contents for Siemens REV24RF

  • Page 1 REV24RF.. RCR10/868 Radio set with 7-day room temperature REV24RF../SET controller Comprising a room temperature controller (with integrated radio transmitter) and receiver with relay outputs • Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large numbers. • Self-learning two-position controller with PID response (patented).
  • Page 2 • Synchronization to radio time signal from Frankfurt, Germany (REV24RFDC). • Manual override of the receiving relay. Type summary Radio set comprising: - Room temperature controller REV24RF with 7-day time switch, Base and receiver RCR10/868 REV24RF/SET Radio set comprising - Room temperature controller REV24RFDC with 7-day time switch,...
  • Page 3 Energy saving mode setpoint Party mode active °C / °F Time signal from Frankfurt Temperature unit °C or °F Date (day - month - year) Heating/cooling/pump on 3 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 4 In party mode, symbol is displayed along with the end of party mode. Minus button Decrease values, set time, or make a selection. 4 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 5 Heatin g ph ase 1 Continuous operating The controller also offers the three 3 continuous modes comfort mode, modes energy saving mode and frost protection mode. 5 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 6 Return the slider to position RUN. Symbol is displayed to the left of the symbol. Press or move the slider to end holiday mode prematurely. 6 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 7 DIP switches 4 OFF and 5 ON: PID 12 Normal controlled system for applications in locations with normal temperature deviations. DIP switches 4 OFF and 5 OFF: 2-point 7 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 8 RUN position during these 10 minutes. Siemens recommends to set the desired settings upon startup, install the REV..DC in the desired location, and not carry out any actions on the REV..DC for the next 10 minutes.
  • Page 9 Frankfurt, atmospheric conditions as well as the on reception location where the REV..DC is installed. Siemens cannot guarantee that the REV..DC can receive the time signal from Frankfurt at any time and any place.
  • Page 10 REV24RF..: This deletes the data saved from all receivers. Data from all receivers After this reset, the REV24RF.. indicates that no more receivers are connected to the room controller. Receiver RCR10/868: Open the RCR10/886 cover. Simultaneously press the "Learn" and override buttons on the...
  • Page 11 • Recalibrate the temperature sensor (see "Sensor calibration") if the displayed room temperature does not match the room temperature measured. • Mount the unit base for the REV24RF.. in the desired location. Mounting the room • See also "Mounting and commissioning notes".
  • Page 12 Switch on RCR10/868 4. Test radio link / Press the Test button on the rear or the REV24RF.. and place the unit in the best RF Identify best RF reception location. Test the radio link between the room controller and all connected reception location receivers.
  • Page 13 On the RCR10/868 press the “Learn“ button for about 4 seconds: The blue LED_2 flashes slowly, learning mode is active. Also press the "Learn" button within 20 minutes on the REV24RF.. : The REV24RF.. now either shows confirmation that receiver (RCR 01, RCR02, etc.) is connected or that connection failed.
  • Page 14 Technical data for room controller REV24RF.. Power DC 3 V General unit data Batteries (alkaline AA) 2 x 1,5 V Life Ca. 2 years Backup of clock when changing battery Max. 1 min (all other data remain in EEPROM) Protection class II as per EN 60 730-1 NTC 10 kΩ...
  • Page 15 0.16 kg REV24RF../SET 0.45 kg Housing front RAL 9003 signal white Color Housing bottom RAL 7038 gray Size Housing with base 88 x 114 x 31.5 mm 15 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 16 AC 24 … .250 V / 16 (2) A Circulating pump Receiver RCR10/868 Actuating device Application examples Instantaneous water heater Atmospheric gas burner Zone valve Cooling unit 16 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 17 Room temperature controller (transmitter) REV24RF.. Receiver RCR10/868 Room temperature controller (transmitter) REV24RF.. Receiver RCR10/868 3-port valve with manual adjustment Magnetic valve Three-port valve with actuator Two-port valve with actuator 17 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...
  • Page 18 Dimensions Room temperature controller (transmitter) REV24RF.. 134,5 83,5 Receiver RCR10/868 15,2 © 2008 Siemens Switzerland Ltd Subject to change 18 / 18 Siemens Room temperature controller radio set REV24RF../SET CE1N2206en Building Technologies 24.04.2008...

This manual is also suitable for:

Rev24rfdcRcr10/868

Table of Contents