ISDN CO / QSIG Master / QSIG Slave—T3D3
Specifies the length of time that the PBX tries to establish L2 in "Permanent" mode.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.29 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN CO / QSIG Master / QSIG Slave—T3D9
Specifies the length of time that the PBX tries to disconnect L2 in "Call by Call" mode.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.29 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN Extension—T200
Specifies the maximum time that the PBX waits for a reply after sending the L2 command to ISDN.
Value Range
0–600 ´ 100 ms
3.29 [1-1] Slot—Card Property - BRI type/PRI type