(2) PR Selection
ADJUSTMENT OBJECTIVE
ERROR
EQUIPMENT AND JIG
ADJUSTMENT METHOD
CAM EE
-
Use the PR Apply Jig program to apply the initial data for the model where PR is applied.
1. Open the PR jig program.
2. Click on the Connect button to connect the communication.
3. After setting the model to PR, press the PR Apply button.
5-2. LENS SELECT TEST
ADJUSTMENT OBJECTIVE
ERROR
EQUIPMENT AND JIG
ADJUSTMENT METHOD
CAM EE
1. Lens select test
2. Test method
1) Test lens: Manual, DC iris, video lens
2) Manual lens: Set the Lens Select Switch at the center and check the screen.
3) DC iris lens: Set the Lens Select Switch to the top and check the screen.
4) Video lens: Set the Lens Select Switch to the bottom and check the screen.
3. Error
1) Iris is full
2) The iris does not recover to normal screen after 3 seconds. (Iris is detected with delay)
3) Iris does not open as black cap.
4) Iris vibrates
TO SAVE THE INITIAL PR VALUE ON MICOM
PR NOT SET
EFP-RC JIG, PC, INTERFACE BOARD
NUMBER OF MEASUREMENT LOCATIONS
CHECK WHETHER IRIS OF EACH LENS IS OPERATING PROPERLY
IRIS OF EACH LENS NOT OPERATING PROPERLY
MONITOR
NUMBER OF MEASUREMENT LOCATIONS
NUMBER OF ADJUSTMENT LOCATIONS ADJUSTMENT SPECIFICATION
NUMBER OF ADJUSTMENT LOCATIONS ADJUSTMENT SPECIFICATION