Input Power; Ec Front Panel - Toshiba IPedge Installation Manual

Hide thumbs Also See for IPedge:
Table of Contents

Advertisement

EC SERVER

Input Power

USB Connectors
Figure 2-2 IPedge EC Server Front Panel
AC Power
PS/2 Mouse
Keyboard
Figure 2-3 IPedge EC Server Rear Panel Connections

EC Front Panel

Buttons
LEDs
2-2
Operating Relative Humidity: 8% to 90% (non-condensing)
100 ~ 240 VAC, 50 ~ 60 Hz
Peak load: 130 W, 1.2 Amp at 120 VAC (tested)
Maximum Inrush Current: 11.5 Amp
System Power LED
Network Activity (2)
Hard Disk Activity
USB
COM 1
VGA
The front panel of the IPedge EM server has push-button switches and
LED indicators. The disk drive is accessible from the front.
The power supply is accessed through the rear panel. All cable
connections are on the rear panel.
Power On/Off Button - This applies or removes system power. When the
power is turned off using this button main power is shut off but standby
power to the system remains on. To completely remove power from the
system use this button to shut down the system then, disconnect the AC
power cord.
Power Up Sequence: Set the rear panel power switch to ON. Wait one
minute then, press the font panel power button.
System Reset Button - Press and release to reset then, reboot the
server.
Power LED - Indicates that system power is on when Illuminated.
System Reset
Power On/Standby
NIC 2