Other Functions; Auto Stop At Tank Full; Power Failure Memory; Low/High Temperature Protection - Sharp DW-D12A Operation Manual

Dehumidifier sharp dw-d12a
Table of Contents

Advertisement

4. AUTO: The Auto indicator is turned on, and the dehumidifier dehumidifies according
to the preset humidity. You can press the HUMIDITY SELECTION (AUTO MODE)
button to set the desired humidity. The setting order is as follows:
60%RH (default) > 70%RH > 80%RH > 40%RH > 50%RH > 60%RH...(cycle)
[When you want to set your desired humidity]
As long as you press the HUMIDITY SELECTION (AUTO MODE) button, the
dehumidifier will go to the AUTO dehumidifying mode and the Auto indicator is turned
on.
When you press the MODE button to set the Auto mode, you can press the HUMIDITY
SELECTION (AUTO MODE) button to cycle among 60%RH, 70%RH, 80%RH, 40%RH
and 50%RH in sequence.
When you press the MODE button to set the LAUNDRY, COMFORT and
CONTINUOUS mode and then press the HUMIDITY SELECTION (AUTO MODE)
button, the dehumidifier will immediately switch to the AUTO function.
You can switch the dehumidifier from the long-term operation mode to the timer mode.
Press the OFF Timer button to cycle among the time in the following order: 2h > 4h >
8h > Off. After the timer is set, the corresponding indicator will be turned on.
Starts or stops the PCI operation. The corresponding indicator will be turned on or off.
Press the SWING button, and the louver swings upward and downward. Press this
button again when the louver reaches your desired position.
Do not push or shake the louver with your hands. When the louver is closed by force,
do not operate the unit.
(Otherwise it may lead to condensation on the main unit surface or a fault.)
12

OTHER FUNCTIONS

AUTO STOP AT TANK FULL

If the water in the water tank reaches the set level when the dehumidifier operates in the dehumidifying
mode, both the compressor and the fan motor stop running, the unit stops operation the buzzer sends out ten
warning sounds, and only the Tank full indicator is on.

POWER FAILURE MEMORY

After you power off the unit by pressing the ON/OFF button, when you power it back on by pressing the
same button, the dehumidifier will begin operating with the mode before it is powered off.
If power fails while the dehumidifier is operating (i.e. the power plug is removed), the dehumidifier will
memorize the operating mode before the power failure and resume this mode automatically after it is
powered back on.

LOW/HIGH TEMPERATURE PROTECTION

The function eliminates the risk that the dehumidifier may operate in an abnormal environment. When the
temperature/humidity sensor of the air inlet detects that the current ambient temperature is lower than or
equal to 0°C or higher than or equal to 40°C (including open circuit or short circuit of the temperature
sensor (NTC)), the dehumidifier will stop running and enable the over-temperature protection function. The
buzzer keeps sending out three long and two short warning tones, all the indicators turn off, and only the
digital display blinks and shows C1.
When the temperature sensor of the copper pipe of evaporator detects that its temperature is higher than
or equal to 40°C within two continuous minutes, the dehumidifier will stop running and enable the
over-temperature protection function. All the indicators turn off, only the digital display blinks and shows C2,
none of the buttons work, and the buzzer does not beeps. In this case, you must power off and back on the
dehumidifier.