3) -2. 02FD
No
Procedure on P.C. side
1
Install the "02FD.EXE" on the P.C.
ALL RAM Data UpLoad : Go to "2"
ALL RAM Data DownLoad : Go to "9"
2
ALL RAM Data UpLoad
Connect the P.C. and the UP-3301 (CH2) via RS232.
4
Execute the "02FD.EXE" on the P.C.
*Please close all other applications while using this utility.
5
Set the Communication method by pushing the "Setting" Button.
Push the "OK" Button.
Push the "[POS 3 PC]" Button.
6
And Select the Receiving File.
7
Communication starts.
8
The UpLoad is completed.
The initial Window is shown.
Push the "Exit" Button.
9
ALL RAM Data UpLoad
Connect the P.C. and the UP-3301 (CH2) via RS232.
No
2
Enter the SRV mode.
Select " 2 SETTING ".
Select " 13 DATA SEND"
3
The UP-3301 displays
7
Push CASH key. The UP-3301 displays
8
The UpLoad is completed.
The SETTING menu is shown.
9
Enter the SRV mode.
Select " 2 SETTING".
Select " 14 DATA RECEIVE"
10
The UP-3301 displays
Push the CASH key.
UP-3301US SERVICE PRECAUTION
– 13 –
Procedure on UP-3301 side