3.3

Specification tables

Model
Running ambient air temp.
Outlet Water Temp.
Minimum Inlet Water Temp.
Maximum Inlet Water Temp.
Power supply
IP rating
Storage size
1)
Water heating (HP cycle)
Water heating (Full mode)
2)
COP
Unit
Sound pressure level at 2 m
Refrigerant type/Mass
Max. refrigerant circuit pressure
3)
PTR valve setting
Throttling type
System protection
Compressor
Fan motor
Water connections
Electric heating element
Table 2
1) Air at 15 °C and voltage supply 230V
2) According to EN255-3 by using air at 20 °C, water inlet at 15 °C and factory settings
3) PTR valve power capacity: 10 kW
Compress 3000 DW FOO
Heating capacity
Max. input
Max. current
1)
Heating capacity
Max. input
Max. current
Dimension (D×H)
Packing (W×H×D)
Net/gross weight
Model
Type
Brand
Input
Model
Brand
Input
Speed
Water inlet
Water outlet
Max. water working pressure
PTR valve joint
Max inlet pressure
Heat exchanger
Rated power input at 230 V
Rated current at 230 V
HP 270-2E 0 FOOV/S
°C
°C
°C
°C
Ph-V-Hz
1ph / 230V-240V / 50 Hz
IP
l
kW
kW
A
kW
kW
A
mm
mm
730 x 2004 x 730
kg
dB (A)
kg
kPa
kPa
Thermal expansion valve
High pressure limiter, Temperature limiter
W
W
r/min
kPa
kPa
Double wall plate heat exchanger
kW
A
Appliance details | 9
-7 °C/+40 °C
setpoint  1 °C
3 °C
70 °C
X4
270
1.5
0.6
2.6
3.15
2.25
9.8
3.3
705 x 1840
113/128
43
R134a / 0.375
2700
1000
WHP01900
Rotary
Highly
700
W1G230EB
EBM Papst
28
1500
¾ BSP inch
¾ BSP inch
1000
½ BSP inch
800
1.65
7.2
6 720 808 869 (2014/06)