4 DIAGNOSTICS
Field
E 09
E 10
E 11
E 12
E 13
E 14
E 15
E 16
E 17
Purchases
Platform ID
Mapped
Platform ID
Family ID
Model ID
Remod
Channel
Time Zone
DST Entry
Time
DST Exit
Time
Current GPS
Time
Description
BATTERY
Dead battery or memory has
not been initialized; occurs if
battery fails to keep the RAM
alive during power-down;
disconnects the set-top
SERIALNO
Invalid serial number
INVALID UNIT
Invalid unit address
ADDRESS
POST ERROR
POST failed
BOOT
Sys_boot initialization failure
STARTUP
System startup failure
TSI INVALID
TSI Structure is corrupted
FLASH BAD
Bad flash number specified
NUMBER
for Initiate Flash Platform
BAD PLATVAL
Bad platform validation step
number
Indicates the number of unreported subscriber event purchases stored on the
product.
A unique 16-bit hexadecimal number that identifies the platform image (also called the
ROM ID).
A unique 16-bit hexadecimal number that identifies the platform image (also called the
ROM ID), used in place of the Platform ID for certain third party applications.
The manufacturer and product family, in hexadecimal
The model, in hexadecimal
The interface to the subscriber TV; channel 3 or 4 in the USA
The time zone offset (in minutes) relative to GMT
The daylight savings entry time.
The daylight savings exit time.
The current time.
Return the set-top for repair;
requires factory initialization
message
Not used
Return the set-top for repair;
requires a unit creation message
Not used
Power cycle the set-top; if
repetitive, return for repair
Power cycle the set-top; if
repetitive, return for repair
Power cycle the set-top; if
repetitive, return for repair
Error logged, ignore
Error logged, ignore
15