Electrical Adjustments
Group/
Item Name
Item
33 Lamp total time(for life test)
40 PreScaler
41 Htime
50 Lamp Replacement Display
51 Filter Warning Display
5 Lamp Counter reset Times
54 Factory Default Execute
Times
55 Motor Disable
56 Menu Position
57 Menu Position
58 Lamp Go Out
59 Souce Search Enable
Group
option (signal)
201
0 FrameLock Option
 Field Sense Invert Enable
3
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
9 Sensivity for Signal Lost
(HSYNC)
10 Sensivity for Signal Lost
(VSYNC)
11 Keystone Filter Center Value Reference Value
Group
option (McI model only)
202
0 Memory Viewer OSD
Group
Lampcontorl
210
0 DIMMER_CTRL_LEVEL1
1
DIMMER_CTRL_LEVEL
 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
8 DIMMER_CTRL_LEVEL9
9 DIMMER_CTRL_LEVEL10
Function
For test purpose
Lamp Warning Display On / Off
Filter Warning Display On / Off
Reset Times of Lamp Counter
Reset times of Fanctory Default
Motors Disable
Move menu (X asis)
Move menu (Y asis)
Source Search Enable
(0:Disable 1:Enable)
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
Memory Viewer OSD Display (1:
Yes, 0: No)
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
Luminance Level  Data for Dimmer:
Dim Level  at the less than the
Value
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the
Value
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the
Value
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the
Value
Luminance Level 6 Data for Dimmer:
Dim Level 6 at the less than the
Value
Luminance Level 7 Data for Dimmer:
Dim Level 7 at the less than the
Value
Luminance Level 8 Data for Dimmer:
Dim Level 8 at the less than the
Value
Luminance Level 9 Data for Dimmer:
Dim Level 9 at the less than the
Value
Luminance Level 10 Data for
Dimmer: Dim Level 10 at the less
than the Value
Initial
n/a
n/a
1
1
0
0
0
0
0
n/a
0
1
0
1
0
0
5
350
3
16
1
-40-
range Note
0-55
n/a
0-65535
n/a
0 - 1
1: On, 0: Off
0 - 1
1: On, 0: Off
0 - 55
Read only
0 - 55
Read only
0 - 1
0: On, 1: Off
0 - 104
0 - 104
0 - 1
0-1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
0 - 1
47Hz (Vfreq) ~ Panel frequency of
input signal
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
0 - 1
Value
1: Enable - Used Reversed FLDINV
Setting Value
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
0 - 1
1:Enable (Service Adjustment
Enable)
0:Zoom Accelerator OFF,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
0 - 1
cancelled)
No last memory
0 - 55
0 - 65535
0 - 55
0 - 30
0 - 1
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55