Sanyo PLC-WXU30 Service Manual page 42

Multimedia projector
Hide thumbs Also See for PLC-WXU30:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
Temp C Warning Offset
17
(Temp)
Temp B-A Warning Offset
18
(Temp)
Temp C-A Warning Offset
19
(Temp)
0 Temp A Warning Offset (Time)
Temp B Warning Offset
1
(Time)
Temp C Warning Offset

(Time)
Temp B-A Warning Offset
3
(Time)
Temp C-A Warning Offset
4
(Time)
5 Factory Mode
Group
Fan control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
 High Fan1 Min
3 High Fan1 Max
4 High Fan Min
5 High Fan Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min
9 High Fan4 Max
Normal Fan Control Min
10
Temp
11 Normal Fan Control Max
Temp
1 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan Min
15 Normal Fan Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Normal Fan4 Min
19 Normal Fan4 Max
0 Eco Fan Control Min Temp
1 Eco Fan Control Max Temp
 Eco Fan1 Min
3 Eco Fan1 Max
4 Eco Fan Min
5 Eco Fan Max
6 Eco Fan3 Min
7 Eco Fan3 Max
8 Eco Fan4 Min
9 Eco Fan4 Max
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
1 Fan Initial Volt
 Fan3 Initial Volt
3 Not used
4 Fan1 Cooling Speed
5 Fan Cooling Speed
6 Fan3 Cooling Speed
7 Not used
8 Cooling Time L1
Function
Temp. C to judge the Temp Error at
Eco (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
For factor use
Temp Senser Control Start/End Temp.
at High
Fan voltage value at High (unit: 0.1V)
Temp Senser Control Start/End Tem.
p at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.
p at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Initial
70
70
7
7
100
100
100
100
100
100
100
100
5
5
15
0
0
5
5
18
1
1
0
Normal Ceiling HiLand-
HiLand-
Normal
Ceiling
45
45
44
44
51
51
44
44
100
100
135
135
135
135
135
135
85
85
130
130
130
130
130
130
75
80
80
85
80
85
80
85
9999
9999
9999
9999
45
45
44
44
51
51
44
44
8
8
15
15
15
15
15
15
75
75
10
10
10
10
10
10
70
65
75
70
75
70
75
70
9999
9999
9999
9999
44
44
44
44
50
50
44
44
63
63
115
115
115
115
115
115
70
70
110
110
110
110
110
110
55
55
55
55
55
55
55
55
9999
9999
9999
9999
70
70
70
9999
130
130
130
9999

-4-
range Note
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-1
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
-
-
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
-
-
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
-
-
0-55
0-55
0-55
-
0-55
0-55
0-55
-
1-15