6.6

Infrared Sensor Connectors

Located at the bottom of each vertical member is an infrared detector. The detector on each vertical
member operates as a safety device if the infrared beam is interrupted. Door can be set to stop if
beams are broken while closing or to stop and reverse to the full open position. Refer to the Pioneer
SC-325 Controller Manual for more information.
1. Locate female connector on vertical member. This connector is attached to the infrared detector.
2. Locate male connector on horizontal member. Unroll cable until connectors meet.
3. Plug connectors together. Make sure connectors interlock.
4. Repeat for both infrared detectors.
5. Cable ties and adhesive mounts are supplied to secure wire to the inside of tracks.
NOTE: For each vertical member, unroll
respective sensor cable attached to
horizontal member until cable reaches the
connector attached to the vertical member.
Plug connectors together. It is
recommended to leave some slack at photo
eyes for replacement purposes.
6.7
Fastening Door Assembly
to Clear Opening
The two diagonals must be within 1/8
Verify dimensions
Diagram 5
Part No. 4801-5154 Rev 4-08
inch.
from Table 1.
1. Use a tape measure and make sure that the
overall height and overall width of the
clear opening meet the requirements:
Overall Height = Height + 20.688 in.
(52.55 cm), Overall Width = Width +
16.4 in. (41.66 cm). Reference Table 1
and Diagram 1.
2. Make sure that door assembly is plumb &
square. See Diagram 5.
500 ST Door
Diagram 4
Page 13 of 25