Page 1
RFID SYSTEMS Mobile Reader SIMATIC RF680M Operating Instructions · 06/2011 SIMATIC Ident Answers for industry.
Page 3
___________________ SIMATIC RF680M Mobile Reader Introduction ___________________ Safety Information ___________________ Description SIMATIC Ident ___________________ Power supply RFID systems ___________________ SIMATIC RF680M Mobile Reader Commissioning ___________________ Operation Operating Instructions ___________________ Software overview ___________________ The software "RF- MANAGER" ___________________ "RF680M" software ___________________...
Page 4
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
The software "RF-MANAGER" ........................ 29 Prerequisites for working with the software "RF-MANAGER" .............29 8.1.1 Necessary components .......................29 8.1.2 Starting the software "RF-MANAGER" ..................29 8.1.3 Preconditions for parameterization of the WLAN connection ............29 SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 6
Table of contents 8.1.4 Settings in the Engineering System .................... 30 8.1.5 Parameterizing the WLAN card in the SIMATIC RF680M mobile reader........30 8.1.6 Enter the IP address in the mobile reader .................. 32 8.1.7 Creating a back-up........................32 Application mode "Remote" ......................32 8.2.1...
Page 7
Kill tag ............................70 9.5.10 Tag Type Selection ........................71 The functions in the "Extras" menu....................72 9.6.1 Overview of the Extras functions ....................72 9.6.2 Password for the SIMATIC RF680M application .................73 9.6.3 Reader status..........................74 9.6.4 Reader settings ..........................75 9.6.5 Settings ............................75 9.6.6 Setting the language ........................78...
Page 8
Table of contents SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
"RF- MANAGER" and "RF680M". Scope of validity of this document This documentation is valid for the SIMATIC RF680M Mobile Reader and describes the delivery status from 12/2010. Further information The present instructions are a supplement to the operating instructions of the basic device PSION WORKABOUT PRO.
Repairs may only be carried out by authorized qualified personnel. WARNING Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or risk of personal injury to the user. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 12
Safety Information 2.1 General safety instructions SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Implementation environment, field of application and features ● Field of application The SIMATIC RF680M mobile readers can be used in a harsh environment. The device is extremely rugged and protected against spray water. The backlit display is easy to read even under unfavorable lighting conditions.
Page 14
3.1 Field of application and features ● API software interface The SIMATIC RF680M mobile reader is supplied with an API software interface that can be used by customized user programs. ● Additional functional units for the SIMATIC RF680M Mobile Reader All other functional units of SIMATIC RF680M, such as barcode scanners and WLAN can be accessed via the interfaces supplied by the PSION device manufacturer.
50 to 60 Hz) for recharging the battery and connecting to PCs via USB port must be ordered separately. This station has a charging bay for an additional replacement battery. See Ordering data (Page 95). Design Design of the SIMATIC RF680M Item Description ①...
RF680M must be in parallel. Note the technical data of the individual transponders. The following figure shows the positioning of transponders in front of the antenna. The maximum working range is achieved above and below the read head. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 17
Description 3.3 Antenna and antenna field Figure 3-2 Positioning of transponders SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 18
Description 3.3 Antenna and antenna field SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
2. Hold the battery at an angle when inserting so that the side of the battery with the direction arrow is inserted into the battery compartment first (see the depiction of the arrow). SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Charging not in progress. Battery fault! The backup battery The backup battery in the SIMATIC RF680M is used for retaining the application data when the main batteries are discharged. It is a rechargeable battery that is charged together with the main battery.
Commissioning Scope of supply The scope of supply of the SIMATIC RF680M comprises the following components. ● SIMATIC RF680M with integrated RFID read/write unit for RF600 ● Documentation in the directory "Flash Disk\SIMATIC RF680M\Documents\deutsch" or "Documents\english": – The SIMATIC RF680M Operating Instructions –...
Switching the device On and Off Requirements for startup ● The mobile reader SIMATIC RF680M is mounted ● The device battery is charged and inserted in the device (see chapters Charging the device (Page 18) and Inserting the battery (Page 17)).
2. Select "Auto Restore" and then confirm with the "-->" button. 3. Select "Default Backup" and confirm this with the "Create Profile" button. Reaction: The backup is started. 4. Click "Finished" to return to the application. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Operating modes The SIMATIC RF680M device has two operating modes: 1. "Supervisor Mode" Configuration and settings for the SIMATIC RF680M Mobile Reader. 2. "User Mode" Default mode. The user can only use the installed service and test applications. The start menu functionality is restricted.
You can also permit or deactivate acoustic signals for different messages by activating the relevant checkboxes. 5.4.3 Set the backlighting of the screen To alter the brightness of the display, select "Start > Settings > Control Panel > Display > Backlight in "Supervisor" mode. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 26
Commissioning 5.4 Basic settings in the operating system SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
If the blue <FN> key is pressed first, the character after the cursor is removed. ⑩ <ESC> Closes the currently open menu, dialog window or started application and returns you to the previous interface. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
If you press a shift key briefly twice in succession, it will become inactive again. The Touch display The screen of the SIMATIC RF680M is designed as a touch-sensitive display. You can easily enter commands by touching it with the pen.
Software overview Software applications Two software applications are available to you in SIMATIC RF680M: ● The software "RF680M" of the standalone product SIMATIC RF680M The application program "RF680M" is primarily intended for use in the service and test fields for reading and writing tags in RFID applications.
Page 30
Software overview 7.2 Overview of possible applications SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Barcode scanner When reading of bar codes is configured in the engineering system of RF-MANAGER, you will need the accessory SIMATIC RF barcode scanner for the SIMATIC RF680M device. Both components can be ordered and installed separately as accessories. [See Ordering data (Page 95) ].
8.1.5 Parameterizing the WLAN card in the SIMATIC RF680M mobile reader Two examples are given below for the procedure that you can follow for configuring the WLAN card of SIMATIC RF680M.
Page 33
With this procedure, the active radio networks are displayed automatically. 1. Set the operating mode to "Supervisor" in SIMATIC RF680M. 2. In SIMATIC RF680M, select "Start > Programs > Summit > SCU" 3. Under "Active Config", select "Third party". 4. To activate these changes, change to the device to the "Powerdown" mode by pressing the blue <FN>...
RF-MANAGER, the SIMATIC RF680M mobile reader has the properties of a stationary reader. This means that the acquired data are only displayed on the reader and transferred to RF-MANAGER. You are not able to acknowledge or reject the acquired data in SIMATIC RF680M. 8.2.1 Acquire data and transfer it to RF-MANAGER...
In application mode "Mobile" that is configured via the Engineering System in RF-MANAGER, you can check the read data for validity in the SIMATIC RF680M mobile reader and reject any faulty reads. Only that data which you have acknowledged will be transferred to RF-MANAGER.
Prerequisites for working in the data editor In order to process tag data, a tag must have been scanned by the SIMATIC RF680M device and its tag ID must be indicated in the display. See Chapter Acquire data and transfer it to RF-MANAGER (Page 33).
Page 37
, the current memory area will be displayed complete in the editor, ⑨ otherwise you can enter values under "Address" [ ] and "Length" [⑩] to display the relevant data area only. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 38
Memory area in which the tag ID is stored. The area is read-only. ① PC: 2 bytes of Protocol Control bits ② EPC: 12 bytes tag ID (in this example: 30112233445566778899AAC0) ③ CRC: 2 bytes of check sums SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 39
Specification for RFID Interface" (EPCTM Radio-Frequency Identity Protocols Class-1 Generation-2 UHF RFID Protocol for Communications at 860 MHz - 960 MHz, Version 1.0.9) See also Acquire data and transfer it to RF-MANAGER (Page 32) SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Figure 8-4 Timeout display You can now stop the command completely with "Yes" or continue it with "No". If you continue, the interrupted command is continued at the point of interruption. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
With this function you can display the complete size of the selected memory area. If the check mark is set for "Complete", "Read all" and "Write all" are displayed on the buttons. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
In the data editor, you can select the required memory area of the tag in which you want to write data, and reduce it, if required, by removing the check mark from "Complete" and entering the address and length in the respective fields. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
You can then scan tags or call a function from the menu. You can find out from the following table which functions are available in the respective application mode. Note If you want to use the function "Edit Tag" in application mode "Mobile", you must activate this in RF-MANAGER. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Overview of file functions The following file functions are available that you can select in the menu via "File": ● Open (with "Edit Tag" function) ● Save Tag (with "Edit Tag" function) SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Via "File > Save", you can save data currently displayed in the editor of the reader to a file on the SIMATIC RF680M. If you select "Save", the current file will be replaced; if you select "Save Tag As", you can select a new directory or a new file name.
Note A connection to RF-MANAGER is established as long as the "RF-MANAGER" software is running on the SIMATIC RF680M. On exiting, this connection is closed down. 8.3.5 The functions in the "Tag" menu 8.3.5.1...
Only keep one tag in the scanning range of the SIMATIC RF680M Ensure that only one tag is in the scanning range of the SIMATIC RF680M when the tag ID is being written. Otherwise, the tag will not be written.
Page 48
● The identifier "w" defines password protection for writing (reading is permitted) ● The identifier "p" specifies permanent locking All the possible combinations of "r/w", "w" and "p" are listed in the table below complete with their significance for the different memory areas. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 49
This memory area can be written from the "Secured" state, but not from the "Open" state. You must know the access password of the tag to write a new ID to the tag. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
● The tag must have a valid kill password (non-zero) ● The password is entered in the interface in the "Kill Password" field. Select "Tag > Kill Tag..." for this purpose. The following window is displayed. Figure 8-11 Kill tag SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Figure 8-12 The Tools functions 8.3.6.2 Password for the RF-MANAGER application. As an option, you can assign a password for the RF-MANAGER application. Select "Tools > Password" from the menu. Figure 8-13 Password SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Version statuses and settings of the RF600 read/write device can be read out with the "Reader Status" function. ● API version ● Model (US or EU) ● Firmware version of the RFID module. Figure 8-14 Reader status SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
You can make the following settings using this function ● Specifying the write and read area of a tag ● Setting data formats Select "Tools > Settings" to parameterize these settings. The "Settings" window opens: SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 54
Depending on the format that you select, the interface in the data editor is as depicted below: Presentation in the data editor for the settings "Byte" "Binary" Presentation in bytes Presentation with "0" and "1" SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 55
Under "Auto-Save Filename" you can define whether the same file with the same name is always updated when scanning tags, or whether new files are saved in each case. Figure 8-17 Auto-Save Filename SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
"Help" menu Using "Help > About" you can obtain information on the following points: ● Information about the device: EU or US version ● Software version ● Manufacturer of the application Siemens AG SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
"RF680M" software Overview of functions When the SIMATIC RF680M application starts up, the screen for scanning tags appears on the display. You can then scan tags or call a function from the menu. Function Shortcut Description File Open Load file from the integral PSION "Flash Disk" directory to the work memory.
Prerequisites for working in the data editor In order to process tag data, a tag must have been scanned by the SIMATIC RF680M device and its tag ID must be indicated in the display. See Chapter Scanning RFID tags and their tag ID (Page 61).
Page 59
Memory area in which, for example, the tag ID is stored. The area is read-only. ① PC: 2 bytes of Protocol Control bits ② EPC: 12 bytes tag ID (in this example: 30112233445566778899AAC0) ③ CRC: 2 bytes of check sums SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
The functions in the "File" menu 9.4.1 Overview of file functions The following file functions are available that you can select in the menu via "File": ● Open ● Save Tag ● Save Tag As SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Via "File > Save", you can save data currently displayed in the editor of the reader to a file on the SIMATIC RF680M. If you select "Save", the current file will be replaced; if you select "Save Tag As", you can select a new directory or a new file name.
9.4.6 Exit You can exit the SIMATIC RF680M program using "File > Exit" or the <ESC> key. You then reach the WinCE operating system level of the PSION Workabout Pro. You require the password relevant to the application for this, if you have previously assigned one.
The time-out display appears when a tag has not been scanned for 20 seconds. Archiving scanned tags To save the list of scanned tags, select "File > Save List As" in the menu. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
During data transfer, the progress of the executing function is displayed in the form of a bar display: Figure 9-5 Progress display The tag function is not interrupted if you briefly move the tag out of the read field. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
These depend on the: • Tag type • Ambient conditions / fixing method of the tag. Under favorable conditions, the limit distances are 250 cm. For additional information, see Technical data (Page 93). SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Page 66
ID of the tag that is located in the field of the SIMATIC RF680M. If this is not the case, time-out will be displayed after 20 seconds. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
With this function you can display the complete size of the selected memory area. If the check mark is set for "Complete", "Read all" and "Write all" are displayed on the buttons. Figure 9-8 "Write All" button SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
8. From the list of tag IDs, select the tag (or the ID) onto which you want to copy the data. 9. Click the "Copy" button. The data will be transferred to the tag. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Only keep one tag in the scanning range of the SIMATIC RF680M Ensure that only one tag is in the scanning range of the SIMATIC RF680M when the tag ID is being written. Otherwise, the tag will not be written.
● The identifier "w" defines password protection for writing (reading is permitted) ● The identifier "p" specifies permanent locking All the possible combinations of "r/w", "w" and "p" are listed in the table below complete with their significance for the different memory areas. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
This memory area can be written from the "Secured" state, but not from the "Open" state. You must know the access password of the tag to write a new ID to the tag. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
● The tag must have a valid kill password (non-zero) ● The password is entered in the interface in the "Kill Password" field. Select "Tag > Kill Tag..." for this purpose. The following window is displayed. Figure 9-11 Kill tag SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
RF640T_GEN2 Siemens tags can be selected directly. For non-Siemens tags, the corresponding tag type is available for selection. For Gen 2 tags, you must also configure the size of the "user memory". Please refer to the technical tag information of the relevant manufacturer for this purpose.
The functions in the "Extras" menu 9.6.1 Overview of the Extras functions The Tools menu contains the following functions that you can select via "Tools": ● Password (application password) ● Reader status ● Reader settings SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Figure 9-14 The "Tools" functions 9.6.2 Password for the SIMATIC RF680M application As an option, you can assign a password for the SIMATIC RF680M application. Select "Tools > Password" from the menu. Figure 9-15 Password 1. Enter a password with up to 8 characters under "New Password".
Version statuses and settings of the RF600 read/write device can be read out with the "Reader Status" function. ● API version ● Model (US or EU) ● Firmware version of the RFID module. Figure 9-16 Reader status SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
You can make the following settings using this function: ● Setting scan mode ● Specifying the write and read area of a tag ● Setting data formats. Select "Tools > Settings" to parameterize these settings. The "Settings" window opens: SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
You can set different formats (for the editor, data, address and length) under "Format" that are explained below. ● Effect of the "Editor" settings: Byte, binary Depending on the format that you select, the interface in the data editor is as depicted below: SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Presentation with "0" and "1" ● Effect of the "Data" settings: Hexadecimal, decimal or ASCII number format "Hex" or "Dec" presentation format can be recognized in the "Address" and "Length" lines in the data editor. ASCII SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
"READ.XML" is set as the default value. See also The data editor (Page 56) 9.6.6 Setting the language You can set the following menu languages for operating the application : ● English ● German SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Language selection window The functions in the "Help" menu 9.7.1 Overview of "Help" menu The "Help" menu contains the following function that you can select via "Help": "About": Figure 9-21 "Help" menu SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Typical application cases for SIMATIC RF680M are shown below. Starting the software To start the SIMATIC RF680M application, click the "RF680M" icon on the desktop. Setting the language of the SIMATIC RF680M application Select the desired language in the "Language selection" window of the "Tools > Language"...
When writing data to the scanned tag, the data that is currently displayed in the editor is written to the tag. Click the "Write" button in the data editor for this purpose (or <Ctrl+W>). Copying tag data See Chapter "Copying tag data (Page 66)". SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Advanced functions When you are using the SIMATIC RF680M as a stand-alone product or in "Mobile" operating mode (configured as editable through the "Edit Tag" function in RF-MANAGER), you can use the extended functions of the SIMATIC RF680M that are described below.
You can download the current version of Microsoft Active Sync from the Internet at Microsoft homepage (http://www.microsoft.com). ● A USB cable for connecting the PC to the SIMATIC RF680M (included in the scope of supply of the docking station) 10.2.2 Working with the Active Sync program The ActiveSync program provides a connection via the USB to RF680M .
Opening the RF680M workstation via ActiveSync and "Explore" Select the button "Explore" (button for German installation: "Durchsuchen") to access ActiveSync on the device. Figure 10-2 Access to the SIMATIC RF680M device via Active Sync "Explore" SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Microsoft Internet Explorer. 10.2.3 Organization of the .XML files in the Flash Disk directory The XML structure for the stored "Tag data" as well as the tag ID list is shown below. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Value 3 = Start address + 3 • ⑥ These values are hidden in this example with "Internet Explorer"; by clicking on the "+" character, the view that is used for the "User" data area can be displayed. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Structure that has arisen from the second save of "Append List". Three tags are read. Presenting the XML file in Excel You can also open the XML file with Excel to obtain a tabular display: Figure 10-5 XML file in Excel SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
10.3 The automatic power-saving function The SIMATIC RF680M has an automatic shutdown function. This is activated if no key on the reader is pressed for approximately three minutes. In addition, the "SIMATIC RF680M" software has a further power-saving function. If no tag is detected for 20 seconds after starting a tag command, or if the tag currently being edited exits the field for longer than 20 seconds, the current tag command is interrupted.
Ensure that the "Flash Disk" directory still contains the files that were supplied on delivery (especially the files with the ending *.pfl). Otherwise, you will have to copy in the files that were backed up on initial commissioning again. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
EN 300 220; FCC Part 15 Transmission frequency EU: 865.6...867.6 MHz USA: 902 to 928 MHz Transmit power Max. 500 mW Compatibility With all SIMATIC RF600 data carriers (tags) Read/write distance to transponder Max. 250 cm SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Ordering data Component Order No. Mobile reader SIMATIC RF680M ETSI: 6GT2813-0BC00 with integrated RFID read/write unit for RF600 FCC: 6GT2813-0BC10 Accessories Order No. SIMATIC RF reader charging/docking station. 6GT2898-0BA00 Charging station for Workabout PRO Incl. wide-range power supply unit with universal adapter, power cable and...
User applications require the SDK development package from PSION (PSION Teklogix Mobile Devices SDK for MS Visual Studio, Microsoft and Visual Studio 2005). You will find further details in the function manual for SIMATIC RF680M that is also saved in the "Flash Disk" directory of the RF680M.
Service & support for industrial automation and drive technologies You can find various services on the Support homepage (http://www.siemens.com/automation/service&support) of IA/DT on the Internet. There you will find the following information, for example: ● Our newsletter containing up-to-date information on your products.
D-90327 Nuremberg. Phone: +49 (0) 180 523 56 11 (€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible) For information about courses, see the SITRAIN homepage (http://www.sitrain.com). SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
The data, energy included, are transmitted across an electromagnetic alternating field. This principle enables contact-free data transmission, ensures high industrial compatibility and works reliably in the presence of contamination or through non- metallic materials. RFID Radio Frequency Identification SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
Because of their wireless design, transponders can be used, if necessary, at individual work locations or manufacturing stations, where their data can be read and updated. SIMATIC RF680M Mobile Reader Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618...
For locking data areas, 46, 68 Tag functions For the operating system, 21 Overview, 44, 60 For the RF-MANAGER application, 49 Tag ID For the SIMATIC RF680M application, 73 Read, 61 Password protection, 12 Write, 45, 67 Passwords Tag standards, 11...