Pressure Testing - Haier HCC2430AGS Installation Instructions Manual

24”, 30” and 36”
Hide thumbs Also See for HCC2430AGS:
Table of Contents

Advertisement

Available languages

Available languages

Pressure Testing

The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 PSIG (3.5 kPa).
This appliance, as well as its individual shut-off valve,
must be disconnected from the gas supply piping
sys-tem during any pressure testing of the system at
test pressures in excess of 1/2 PSIG (3.5 kPa).
When checking appliance regulator function, make
certain pressure of natural gas supply is between 6
and 14 inches of water column or, if converted for LP
gas, between 11 and 14 inches.
THE PRESSURE TESTING SHOULD BE
PER-FORMED BY MEANS OF THE INJECTOR
THREAD ZONE
Gas test inlet
Figure 13.
Pressure Test Method
x
Remove grate and burner cap
x
Remove aluminum gas spreader
x
Temporarily remove the injectors
x
Connect the pressure Test instrument into injector
holder thread zone (M6x0,75)
x
Check if the cooktop has the correct pressure
x
Fix the injector removed for testing and replace
the parts in the right position.
Thread
Cooktop Installation Manual
ENGLISH
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcc3430agsHcc6430ags