Fw 200 Outdoor Reset Heating Control Quick Start (Optional Accessory); Setting Date And Time; Setting Constant Heating (No Night Set Back); Setting Type Of Heating System - Bosch KBR16-3 Installation And Service Instructions Manual

Greenstar fs/combi fs
Table of Contents

Advertisement

8.5
FW 200 outdoor reset heating control quick start
(optional accessory)
This is a quick reference to highlight the BASIC
programming of this control. For a more in depth
understanding or complete programming of the control,
please refer to the FW 200 Installation and Operating
manuals.
Instructions for programming
In the following description, at any time, pressing the
menu button ( Fig. 57, [3]) will bring you back to the
standard display.
8.5.1

Setting date and time

Set date and time upon initial start-up:
▶ Turn the dial
( Fig. 57, [1]) to adjust time and date.
▶ Press the dial
to confirm the setting.
You will be asked about system configuration, which is only necessary if
you have added additional controls.
▶ Press and hold the menu button
prompt disappears.
Set Date and Time after initial programming:
menu
▶ Press the menu button
Vacation will be highlighted.
▶ Turn the dial
( Fig. 57, [1]) counter-clockwise until General
settings is highlighted.
▶ Press the dial
.
Time and date will be highlighted.
▶ Press the dial
.
Time will be highlighted.
▶ Press the dial
.
▶ Turn the dial
to adjust the time.
▶ Press the dial
to confirm the setting.
▶ Turn the dial
until Date is highlighted.
▶ Press the dial
.
▶ Turn the dial
to adjust the date.
▶ Press the dial
to confirm the setting.
8.5.2

Setting constant heating (no night set back)

This can be done two ways:
• By turning the selector ( Fig. 57, [2]) to the comfort symbol (
• Or by changing the programming.
To change programming:
menu
▶ Press the menu button
Vacation will be highlighted.
▶ Turn the dial
one click counter-clockwise to highlight Heating.
▶ Press the dial
.
Program will be highlighted.
▶ Press the dial
.
Activate will be highlighted.
▶ Turn the dial
one click to highlight Edit.
▶ Press the dial
.
A: Program A will be highlighted.
▶ Press the dial
.
Replace with preset program will be highlighted.
▶ Turn the dial
counter-clockwise to highlight All days.
Greenstar FS
menu
( Fig. 57, [5]) until this
( Fig. 57, [5]).
( Fig. 57, [3]).
▶ Press the dial
P1 will be highlighted.
▶ Press the dial
The display will fl ash.
▶ Turn the dial
one click clockwise to 12:00PM.
▶ Press the dial
▶ Turn the dial
until Comfort
The area around the display should fill in.
▶ Press the dial
▶ Press menu button
8.5.3

Setting type of heating system

There are three separate default presets: Baseboard,
Radiators, Radiant Floor. They have an approximate
base point of 75 °F. With this base point, the heating
system will take some time to raise the room
temperature in warmer weather. Please see the FW 200
Installation and Operating Instructions, "Heating circuit
parameters" for more details on those presets. For a
custom preset, see below.
▶ To open INSTALLER SETTINGS: press and hold the menu button
menu
for approx. 5 seconds.
System configuration will be highlighted.
▶ Turn the dial
one click counter-clockwise to highlight Heating
parameters.
▶ Press the dial
Heating circuit 1 will be highlighted.
▶ Press the dial
Heating circuit type will be highlighted.
▶ Press the dial
Radiators will be highlighted.
▶ Press the dial
Radiators will fl ash.
▶ Turn the dial
to choose Baseline/Design temp.
▶ Press the dial
Heating circuit type will be highlighted.
▶ Turn the dial
counter-clockwise.
Base line will be displayed.
▶ Press the dial
This is the supply temperature at 65 °F (18 °C) outdoor temperature.
▶ Set accordingly ( Fig. 58).
▶ Press the dial
).
For hydroair systems, the minimum supply temperature
must be raised to the turn on temperature for that coil.
▶ Turn the dial
until Design Temp will be highlighted.
▶ Press the dial
168 °F (75 °C) will fl ash. This is the supply temperature at 5 °F
( – 15 °C) outdoor temperature.
▶ Set accordingly ( Fig. 58).
▶ Press the dial
Refer to the FW 200 Installation and Operating
Instructions for more custom settings.
Commissioning | 51
.
.
to confirm the setting.
appears.
to confirm the setting.
menu
to return to main display.
.
.
.
.
.
and 78 °F (25 °C) will fl ash.
to confirm the setting.
.
to confirm the setting.
6 720 810 590 (2015/05)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbr28-3Kbr35-3Kwb28-3Kbr42-3Kwb35-3Kwb42-3 ... Show all

Table of Contents