Download Print this page

Fujitsu fi-6010N Cleaning Instructions

Network adf scanner
Hide thumbs Also See for fi-6010N:

Advertisement

BEFORE CLEANING
Push the ADF release button,
hold both sides of the top cover
and lift open
ADF
Cover
ADF Release
Button
Ultrasonic
Sensor
Turn the Scanner
Pad Assy
Wipe downwards. When cleaning take care to prevent the wipe from catching on the metal
parts.
ADF Glass Surfaces x 2
Located on the ADF cover and opposite side. Clean lightly.
Pick Roller
Clean lightly taking care not to scratch the surface.
Ultrasonic Sensor
Clean lightly.
Eject Rollers x 4
Clean lightly taking care not to roughen the surface.
f i - 6 0 1 0 N N e t w o r k A D F S c a n n e r
OFF
while cleaning the following locations
Using F1 Impregnated Cleaning Wipes
C l e a n i n g I n s t r u c t i o n s f o r
It is recommended that these items be
cleaned
EVERY 1,000 SCANS
Consumables
Consumable Kit
Cleaning Kit
Feed Rollers
Pad Assy.
Glass
Part Number
CON-3289-003A
SC-CLE-WGD
Pick Roller
Eject Rollers
P.T.O.

Advertisement

loading

Summary of Contents for Fujitsu fi-6010N

  • Page 1 C l e a n i n g I n s t r u c t i o n s f o r f i - 6 0 1 0 N N e t w o r k A D F S c a n n e r BEFORE CLEANING It is recommended that these items be Push the ADF release button,...
  • Page 2: Turn The Scanner On

    Cleaning Instructions for fi-6010N Scanner PFU Imaging Solutions Europe Ltd Feed Rollers Pad Assy. Ultrasonic Pick Roller Sensor Eject Rollers Glass Turn the Scanner while cleaning the following locations Using F1 Impregnated Cleaning Wipes Feed Rollers x 2 On the “Main Menu” screen press the “Maintenance ”button.