Sign In
Upload
Manuals
Brands
DELL Manuals
Adapter
MARVELL QLogic QLE2662-DEL
DELL MARVELL QLogic QLE2662-DEL Manuals
Manuals and User Guides for DELL MARVELL QLogic QLE2662-DEL. We have
1
DELL MARVELL QLogic QLE2662-DEL manual available for free PDF download: User Manual
DELL MARVELL QLogic QLE2662-DEL User Manual (160 pages)
Fibre Channel Adapter
Brand:
DELL
| Category:
Adapter
| Size: 7.81 MB
Table of Contents
Table of Contents
3
Introduction
11
Intended Audience
11
User's Guide Content
11
Related Materials
12
Documentation Conventions
12
Functionality and Features
14
Functional Description
14
Key Features
15
Supported Operating Systems
15
Microsoft
15
Red hat
16
Suse
16
Vmware
16
Citrix
16
Hardware Installation
17
Hardware and Software Requirements
17
Safety Precautions
17
Pre-Installation Checklist
18
Pcie Bus Slot Considerations
18
Installing the Adapter
19
Connecting to the SAN
20
Driver Installation and Configuration
21
Windows Driver Installation and Configuration
22
Running the Dell Update Package in the GUI
22
Running the Dell Update Package from the Command Line
27
Examples
28
Linux Driver Installation and Configuration
28
Installation Overview
28
Installing the Linux Fibre Channel Driver
29
Building the Driver for RHEL 7.X and
29
Building the Driver for SLES 12 SP3 and SLES 15/15 SP 1
30
Vmware Driver Installation and Configuration
31
Installation Overview
31
Installing the Esxi 6.7 U2 and 6.5 U3 Fibre Channel Driver
32
Updating an Existing Driver or Installing a New Driver for an Existing Esxi 6.7 U2 and 6.5 U3 Installation with Esxcli
32
Verifying the Version of the Installed Driver
33
Installing the Qconvergeconsole Vmware Vcenter Server Plug-In
33
Installing the Qconvergeconsole Vmware Vcenter Server
33
Installation Package Contents
34
Plug-In
34
Plug-In Unregistration from a Manual Install
39
Uninstalling the Qconvergeconsole Vmware Vcenter Server Plug-In
40
Installing the Qlogic Adapter CIM Provider
40
Uninstalling the Qlogic Adapter CIM Provider
43
Installing the Qconvergeconsole Vmware Vsphere Web Client Plug-In
44
Before You Begin
44
Installing Qconvergeconsole Vmware Vsphere Web Client Plug-In
45
Uninstalling the Qconvergeconsole Vmware Vsphere Web Client Plug-In
46
Configuring VM-ID
46
Fibre Channel Configuration
47
Updating the Dell Firmware
48
Running the Firmware Update by Double-Clicking
48
Running the Firmware Update from the Command Line
51
Using Fast!Util for Custom Configuration
52
Configuration Settings
53
Adapter Settings
53
Selectable Boot Settings
55
Restore Default Settings
56
Raw NVRAM Data
56
Advanced Adapter Settings
56
Scan Fibre Devices
57
Fibre Disk Utility
57
Loopback Data Test
58
Select Adapter
58
Exit Fast!Util
58
Setting Fibre Channel Adapter Parameters
58
Setting Fibre Channel Adapter Parameters with
59
Qconvergeconsole GUI
59
Setting Fibre Channel Adapter Parameters with Interactive
59
Qconvergeconsole CLI
59
Setting Fibre Channel Adapter Parameters with Noninteractive
59
Configuring Target Persistent Binding
59
Configuring Persistent Binding with Qconvergeconsole GUI
60
Configuring Persistent Binding with Interactive
60
Qconvergeconsole CLI
60
Configuring Persistent Binding with Noninteractive
61
Qconvergeconsole CLI
61
Configuring Boot Devices
61
Configuring Boot Devices with Qconvergeconsole GUI
61
Configuring Boot Devices with Interactive Qconvergeconsole CLI
61
Configuring Boot Devices with Noninteractive
62
Qconvergeconsole CLI
62
Configuring Boot Devices with the BIOS
62
Configuring Virtual Ports (NPIV)
62
Configuring NPIV with Qconvergeconsole GUI
63
Configuring NPIV with Interactive Qconvergeconsole CLI
63
Configuring NPIV with Noninteractive Qconvergeconsole CLI
63
Configuring NPIV Quality of Service
64
Setting Qos by Bandwidth
65
Setting Qos by Priority
68
Configuring Fibre Channel Driver Parameters
69
Configuring Fibre Channel Driver Parameters with
69
Qconvergeconsole GUI
69
Configuring Fibre Channel Driver Parameters with Interactive
69
Qconvergeconsole CLI
69
Configuring Fibre Channel Driver Parameters with Noninteractive
69
Qconvergeconsole CLI
70
Configuring Fibre Channel Driver Parameters with Qconvergeconsole Vmware Vcenter Server Plug-In
70
Configuring Selective Luns
70
Configuring Ooofr
71
Configuring Ooofr with QCC GUI
71
Configuring Ooofr with Interactive QCC CLI
71
Configuring Ooofr with Noninteractive QCC CLI
71
Configuring the UEFI Driver
72
Setting Queue Depth
79
Changing the Windows Queue Depth
80
Changing the Linux Queue Depth
80
Changing the Esxi Queue Depth
81
Setting an FA-PWWN
81
Setting the FA-PWWN from the Adapter
81
Setting FA-PWWN with Qconvergeconsole GUI
82
Setting FA-PWWN with Qconvergeconsole CLI
83
Setting FA-PWWN with Qconvergeconsole Vmware Plug-Ins
85
Setting the FA-PWWN from the Brocade Switch
86
Setting the FA-PWWN from the Switch
86
Setting the Static FA-PWWN from the Switch
86
Configuring and Verifying FA-BLD
87
Configuring FA-BLD from the Adapter
87
Enabling Host Bus Adapter Port BIOS and Fabric-Assigned Boot LUN with Qconvergeconsole GUI
87
Configuring the Adapter and Boot Devices with Qconvergeconsole CLI
89
Configuring a Zone in a Brocade Switch
90
Verifying that FA-BLD Is Operational
91
Adapter Side Restrictions
92
Using a Fabric-Assigned Boot LUN
93
Using a Fabric-Assigned Boot LUN in Qconvergeconsole GUI
93
Using a Fabric-Assigned Boot LUN in Interactive Qconvergeconsole CLI
93
Using a Fabric-Assigned Boot LUN with Noninteractive
93
Qconvergeconsole CLI
93
Using a Fabric-Assigned Boot LUN with Qconvergeconsole Plug-Ins
94
Running Diagnostics-Fibre Channel Ping and Trace Route
95
Pinging and Viewing Trace of Routing Using Topology Map
95
Running a Fibre Channel CT Ping Test
96
Running a Fibre Channel CT Ping from Qconvergeconsole GUI
96
Running a Fibre Channel CT Ping from Qconvergeconsole CLI
97
Running a Fibre Channel CT Ping from Qconvergeconsole Vmware Plug-Ins
98
Fibre Channel Trace Route
98
Configuring CS_CTL Qos
100
CS_CTL Qos Features
100
Enabling CS_CTL Qos Mode for the Initiator and Target Ports
101
Verifying and Confirming CS_CTL Mode Setup for each Port
101
Creating a Virtual Port from the Adapter's Port in Qconvergeconsole GUI
101
Setting the Qos Priority Level for a Virtual Port in Qconvergeconsole GUI
103
Configuring End-To-End CS_CTL Qos
103
Configuring CS_CTL Qos on the Switch
104
Configuring CS_CTL Qos on the Storage Device
105
Changing the Qos Priority Levels
105
Changing the Priority Levels in Windows
105
Changing the Priority Levels in Vmware Esxi
107
Configuring FDMI
109
Brocade Switch FOS CLI
110
Fabric Features
111
FDMI Enhancements Support
112
Enabling Qlogic Forward Error Correction
114
FEC Process Overview
114
Enabling Qlogic FEC
115
Running Extended Link Service Commands
116
Link Cable Beacon Extended Link Service Command
117
Read Diagnostic Parameters Extended Link Service Command
117
NVM Express over Fibre Channel Hardware and Software Requirements
120
Adapters
120
Operating Systems
120
Host Software
121
Host Setup
122
Setting up the Host
122
Linux Host Setup
122
Windows Host Setup
126
Verifying the Adapter Firmware
126
Verifying Adapter Firmware
126
Verifying the Availability of FC-Nvme Devices
127
Verifying in Linux
127
Verifying in Windows
128
Limitations and Known Issues
129
Unloading and Reloading the Linux Driver
130
Troubleshooting
131
Fibre Channel Diagnostics
131
Fibre Channel Diagnostics Using Qconvergeconsole GUI
131
Fibre Channel Diagnostics Using Interactive
133
Qconvergeconsole CLI
133
Fibre Channel Diagnostics Using Noninteractive
133
Fibre Channel Troubleshooting Diagram
134
Troubleshooting with a Diagnostic Port (D_Port)
135
Configuring D_Port on a Brocade Fibre Channel 16G Switch
136
Configuring and Running Diagnostics Port on a Cisco Fibre Channel 16 Switch
137
Checking D_Port Results from a Brocade Fibre Channel 16G Switch
138
Verifying D_Port Mode with Qconvergeconsole GUI
139
Verifying D_Port Mode with Interactive Qconvergeconsole CLI
139
Verifying D_Port Mode with Noninteractive
140
Qconvergeconsole CLI
140
Verifying D_Port Mode with Qconvergeconsole Plug-Ins
141
Specifications
142
Physical Characteristics
142
Power Requirements
143
Standards Specifications
143
Interface Specifications
144
Environmental Specifications
144
Qconvergeconsole GUI
145
Introduction to Qconvergeconsole GUI
145
Downloading Qconvergeconsole Documentation
146
Downloading and Installing Management Agents
146
Installing the Agents from the Marvell Web Site
146
Installing the Agents Using the Built-In Agent Installer
147
Installing Qconvergeconsole GUI
147
Installing Qconvergeconsole in a Windows Environment
148
Installing Qconvergeconsole in a Linux Environment
149
Installing Qconvergeconsole in Silent Mode
150
What Is in the Qconvergeconsole Help System
150
Regulatory Information
152
Warranty
152
Regulatory and Compliance Information
152
Laser Safety, FDA Notice
152
Agency Certification
153
EMI and EMC Requirements
153
Product Safety Compliance
154
Adapter Leds
155
Revision History
157
Advertisement
Advertisement
Related Products
DELL MARVELL QLogic QLE2660-DEL
DELL MARVELL QLogic QLE2690-DEL
DELL MARVELL QLogic QLE2692-DEL
DELL MARVELL QLogic QLE2692L-DEL
DELL MARVELL QLogic QLE2690L-DEL
Dell QLogic QL45212
Dell Qlogic QME8242
DELL MARVELL QLogic QME2662-DEL
DELL MARVELL QLogic QME2692-DEL
Dell QLE8262
DELL Categories
Laptop
Desktop
Server
Monitor
Storage
More DELL Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL