Table of Contents
5
1 Introduction to the FUS1020 NEMA-4 Flowmeter
12
System Hardware Description
12
Introduction to the FUS1020 Operating System
12
Installation Menu Overview
13
Overview of Real-Time Data Collection
13
Standard Features
13
Integral Datalogger
14
Analog Outputs
14
Performance Specifications (Example for Typical 6-Inch Pipe)
14
Mechanical, Electrical, Environment and Safety Specifications
15
Dual Channel Flow
16
Dual Path Flow
16
Channel 1+2 Flow
16
Clamp-On Transit-Time Theory of Operation
17
Channel 1-2 Flow
17
Wide Beam Tramsmission
18
Flow Calibration Factor
19
2 Getting Started
20
Important Safety Considerations
20
Power Connections
20
Input Power Connector (P1) and Fuse (F1) Locations
20
Power Supply Wiring
21
The Menu Lockout Switch
22
Flowmeter Installation Summary
22
Flowmeter Installation Flowchart
23
Choosing a Programming Interface
25
Overview of the 5-Key Touch Keypad
25
Overview of the RS-232 Interface
25
Installation Menu Operation with the Keypad
26
Accessing and Leaving the Installation Menu
26
System 1020 Installation Menu Structure
27
Installation Menu Structure
27
How to Use the Keypad to Enter Data
30
How to Select Items from an Option List
30
A Note on Multiple Select Option Lists
31
How to Enter Numeric Data
31
How to Enter Alphanumeric Strings
33
How to Use the RS-232 Interface
34
The RS-232 Interface Cable
34
Establishing Communications Using Hyperterminal
35
Accessing the Installation Menu
36
Data Display Mode
37
Data Entry Using the RS-232 Interface
37
Accessing and Leaving the Installation Menu
37
Navigating through the Installation Menu
38
Introduction to the 1020 Menu Screens
39
Typical 1020 Installation Menu Screen
39
Explanations of Installation Menu Callouts
39
Data Entry Procedures Using the RS-232 Interface
40
Entering Alphanumeric Strings
40
Selecting Items from an Option List
41
Multiple Select Option Lists
43
Entering Numeric Data
43
How to Set up a Channel for Transit-Time Operation
44
How to Access the Channel Setup Menu and Create a Site
44
How to Enter Pipe Data
45
How to Select a Liquid Type
46
How to Manually Select Transducers and a Mounting Mode
47
Installing the Transducers
49
Setting the Zero Flow Level
51
Performing the Actual Zero Routine
51
Using the Reversamatic Routine
53
3 Hardware Installation Guide
56
Input/Output Wiring
57
1020N Input/Output Wiring (TB1 and TB2)
57
1020DN Input/Output Wiring (TB1 and TB2)
58
Preparing to Mount the Transducers
59
How to Indentify 1021 Transducers and Mounting Hardware
59
Selecting a Location for Clamp-On Transducers
59
Clamp-On Transducer Mounting Modes
60
Preparing the Pipe
61
Sonic Coupling Compound Recommendations
62
Reflect Mode Transducer Installation
63
Dual Mounting Track Assembly/Transducer Installation
63
Dual Mounting Track Assembly/Transducer Installation for Dual Channel Integrated 1020 Flowmeter
67
Single Mounting Track Assembly/Transducer Installation
68
Figure
70
Single Mounting Track Assembly/Transducer Installation for Single Channel Integrated 1020 Flowmeter
71
Confirm Installation Is Functional by Completing Flowmeter Menu
73
Connect Transducer Cables Ensuring Upstream/Downstream Orientation Is Correct (Figure 3)
73
Integrated Flowmeter Secured to Mounting Track Cover Assembly
73
Figure 6
73
Direct Mode Transducer Installation
74
Dual Mounting Track Assembly/Transducer Installation
74
Connect Transducer Cables
74
Dual Mounting Track Assembly/Transducer Installation for Dual Channel Integrated 1020 Flowmeter
81
How to Identify 1011 Transducers and Mounting Hardware
82
Reflect Mode - Mounting Frames and Spacer Bar
82
Reflect Mode with Spacer Bar Only
84
Direct Mode - Mounting Frames, Spacer Bar and Mounting Guides
85
Using 1012T Mounting Tracks
90
Installing a 1012T Mounting Track in Reflect Mode
90
Installing a 1012T Mounting Track in Direct Mode
92
4 Operating System 1020 with Flow Tubes
95
General Installation Guidelines
95
Liquid Applicability and Compatibility
95
Flow Tube Mounting Location
96
Flow Data Scatter and Damping
97
Considerations for Critical Applications
97
How to Set up System 1020 for Flow Tube Operation
98
Overview
98
Setup Procedure
98
Specifications - CPVC Flow Tube
103
Specifications - KYNAR PVDF Flow Tube
103
Specifications - TEFLON PFA Flow Tube
104
Specifications - 316 Stainless Steel Flow Tube
104
Additional Installation Notes
105
5 System 1020 Application Notes
107
Considerations for Critical Applications
107
To Obtain Technical Assistance
107
Flow Velocity Range
108
Overview of System Performance
108
Picking the Appropriate Transducer
108
Pipe Dimensions
108
Accuracy
109
Data Drift
109
Flow Conditions
110
Low Flow Rates
110
Flow Data Scatter and Damping
110
Data Scatter
109
Data Stability
109
Repeatability
109
Smartslew
110
Notes on Liquid Conditions
111
Erroneous Liquid Parameter Specification
111
Liquid Compatibility
111
Aeration
111
Slurries
112
Two-Phase Liquids
112
Viscous Liquids
112
Temperature and Pressure Ratings
112
System 1020 Damping and Slewing Controls
110
Time Average
110
Overview of System 1020 Memory Resources
112
Reference Tables
113
Vps Values (in Inches/Second) for some Common Metals
114
Sonic Velocity of Pure Water Relative to Temperature
115
System 1020 Reynolds Compensation Factor
116
Terminology Chart
117
The Meter Facilities Menu
119
The Meter Type Menu
119
The Clamp-On Menu
120
General Installation Menu Notes
123
6 The 1020 Installation Menu
123
How to Recall a Site Setup
124
The Channel Setup Menu
124
How to Enable and Disable a Measurement Channel
125
How to Create/Name a Site Setup
126
How to Enable/Disable Site Security
126
How to Delete a Site Setup
127
How to Save/Rename a Site Setup
127
The Pipe Data Menu
128
How to Select a Pipe Class
130
How to Select a Pipe Size
130
Pipe Data Menu Structure
130
How to Enter the Pipe OD (In. or MM)
131
How to Enter the Wall Thickness
131
How to Select a Pipe Material
131
Liner Material
132
Liner Thickness
132
The Application Data Menu
132
Application Data Menu Structure
133
How to Edit the Estimated Vs (Liquid Sonic Velocity)
134
How to Select a Liquid Class
134
How to Edit the Density (SG) Setting
135
How to Edit the Viscosity (Cs) Setting
135
Pipe Configuration
136
Pipe Temperature Range
136
Pipe Configuration Menu Structure
137
Pipe Configuration Option List Definitions
137
The Pick/Install XDCR Menu
138
How to Select a Transducer Model
139
Pick/Install Xdcr Menu Structure
139
How to Select a Transducer Size
140
How to Select a XDCR Mount Mode
140
How to Use the Spacing Offset
141
Reviewing the Spacing Method
141
The Number Index Menu Cell
141
How to Use [Install Complete?]
142
The Ltn Menu Cell
142
Force Transmit Procedure
143
How to Use the Actual MTY Command
146
The Empty Pipe Set Menu
146
How to Use the Mtymatic Command
147
How to Use the Set Empty Command
147
Actual Zero
148
Autozero
148
Reversamatic
148
Zero Flow Adjust Menu
148
Zeromatic (Description)
148
Using Actual Zero
149
Using Reversamatic
149
Zeromatic (Optional Function)
150
Operation Adjust Menu Structure
152
The Operation Adjust Menu
152
Damping Control
153
Deadband Control
153
Memory Delay (Sec)
154
Memory/Fault Set
154
The Flow/Total Units Menu
154
Totalizer Controls
155
The Flow/Total Units Menu Structure
156
Flow Time Units
157
Flow Volume Units
157
Flow Display Range
158
Flow Display Scale
158
Total Volume Units
158
Total Resolution
159
Totalizer Scale
159
Batch/Sample Total
160
Reset Totalizer
160
The Data Span/Set/Cal Menu
160
Totalizer Mode
160
Span Data
161
The Data Span/Set/Cal Menu Structure
161
Pgen
162
Max Flow
163
Max Vs M/S
163
Min Flow
163
Min Vs M/S
163
Hi Flow
164
Interface Vs (M/S) Meters-Per-Second
164
Low Flow
164
Set Alarm Levels
164
Aeration
165
Makeup Latch
165
Calibrate Flowrate
166
Kc Calibration
166
Multipoint Calibration
166
The Datalogger Setup Menu
168
The Datalogger Setup Menu Structure
169
Alarm Letter Codes and Descriptions
170
Datalogger Data
170
Datalogger Mode
170
Datalogger Events
171
Log Time Interval
171
The I/O Data Control Menu
172
Analog out Setup Data Categories
173
Analog Output Setup
173
Assigning Io Output Functions
173
System 1020 Analog Outputs
173
The I/O Data Control Menu Structure
173
Assigning Relay 1 Functions
174
Relay 1 Option List
174
Relay Setup
174
The Meter Facilities Menu
175
Pipe Table
176
Preferred Units
176
The Table Setups Menu
176
Pipe Table Menu Structure
177
Create/Edit Pipe
178
Delete Pipe
179
Transducer Type Menu
179
The Datalogger Control Menu
180
Transducer Type Menu Structure
180
Circular Memory
181
Datalogger Control Menu Structure
181
Output Datalogger
181
Clear Datalogger
182
Est Log Time Left
182
The Memory Control Menu
182
Analog Output Trim Menu Structure
183
Current Output Trim (Io1 & Io2)
183
PGEN Output Trim (Single Channel Models Only)
183
The Analog Output Trim Menu
183
Clock Set Menu Structure
184
Date
184
The Clock Set Menu
184
Time
184
Baud Rate
185
RS-232 Setup
185
Setup
185
Setup Menu Structure
185
Data Bits
186
Line Feed
186
Parity
186
Network ID
187
RTS Key Time
187
System Info
188
Activating the Display
188
System Info Menu Structure
188
Data Display Screen
188
Selecting Display Data Items
189
Section 7 7. the Diagnostic Data Menu
190
Main Diagnostics Screen
191
Diagnostic Main Menu Description
191
Flow Data Menu
191
Flow Data Menu Items
192
Ancal
193
The Application Info Menu
194
Hiflow and Loflow
193
Vs M/S
193
Application Info Menu Items
194
The Liquid Data Menu
194
Liquid Data Menu Items
195
The Site Setup Data Menu
195
Site Setup Menu Items
195
Introduction to [HF] Menu Item
196
Using the [HF] Menu Item
196
Manual" Adjustment Procedure
197
Automatic" Adjustment Procedure
198
The Test Facilities Menu
199
Makeup
199
Troubleshooting Tips
200
Test Facilities Commands
199
Flow Computer Messages
200
Using the 1020 Reset Sequence
202
System Reset Using the Keypad
202
System Reset Using the RS-232 Interface
203
Appendix Aengineering Drawings
205
Appendix B Site Setup Considerations for 1010/1020N Blind Systems
229
Index
238
Advertisement
Advertisement
Related Products
Siemens SITRANS FUS380
Siemens FUS1010
Siemens FUS1010 IP65 NEMA 4X
Siemens FUS1010 IP66 NEMA 7
Siemens SITRANS FUS080
Siemens SITRANS FUH1010PVX
Siemens FUG1010 IP65 NEMA 4X
Siemens SITRANS FUE950
Siemens SITRANS FUT1010 & IP66 NEMA 7
Siemens FUH1010 IP65 NEMA 7 Compact
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL