LG LRE30451S Installation Manual
LG LRE30451S Installation Manual

LG LRE30451S Installation Manual

Electric
Hide thumbs Also See for LRE30451S:

Advertisement

Website: http://us.lge.com
Installation Manual
Electric Range
LRE30451S / LRE30755S
Please read these instructions thoroughly before
installing and operating the range.
P/No.: 3828W5U0512

Advertisement

Table of Contents
loading

Summary of Contents for LG LRE30451S

  • Page 1 Website: http://us.lge.com Installation Manual Electric Range LRE30451S / LRE30755S Please read these instructions thoroughly before installing and operating the range. P/No.: 3828W5U0512...
  • Page 2: Before You Begin

    Part 1 SAFETY PREPARE TO INSTALL THE RANGE BEFORE YOU BEGIN Remove all tape and packing materials before using TOOLS NEEDED the range. Dispose all plastic bags after unpacking the range. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS WARNING If the information in this manual is not followed exactly, a fire or electrical shock may...
  • Page 3: Prepare To Install The Range

    Part 2 PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS IMPORTANT SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR. CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. For installation in CANADA, a Free-standing range is not to be installed closer than 12 mm from any adjacent surface.
  • Page 4: Electrical Connection Requirements

    Part 3 ELECTRICAL CONNECTIONS ELECTRICAL CONNECTION 3, 4 - Wire electrical wall Receptacle types REQUIREMENTS This appliance must be installed and grounded on a 4 Wire receptacle (14-50R) branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO. 70 - latest edition.
  • Page 5 Part 3 ELECTRICAL CONNECTIONS 3-wire connection with a power supply cord WARNING The middle (neutral or ground) wire of the power cord or 3-wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block.
  • Page 6 Part 3 ELECTRICAL CONNECTIONS Follow the instructions under “Install the power cord as 4-wire connection follows” on page 5 to correctly install the strain relief. 1. Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 7.) Remove the ground screw and retain it.
  • Page 7 Part 3 ELECTRICAL CONNECTIONS 1. Loosen the lower 3 screws from the terminal block. 3-wire connection (Refer to Figure 11.) 2. Insert the bare wire (white/neutral) end through the center terminal block opening. Do not remove ground strap connections. 3. Insert the two side bare wire ends into the lower left and the lower right terminal block opening.
  • Page 8: Install The Range

    Part 4 INSTALL THE RANGE Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the three screws. Use a spirit level to check your adjustments. Place the level diagonally on the oven rack, and check each direction for level.