Removing And Installing The Lamp Unit - Sharp XV-Z3100U Service Manual

Hide thumbs Also See for XV-Z3100U:
Table of Contents

Advertisement

XV-Z3100U/XV-Z3100/XV-Z3300/DT-510
Removing and Installing the
Lamp Unit
Warning!
• The lamp unit becomes very hot while the pro-
jector is operating. Do not remove the lamp
unit from the projector right after use. The lamp
and parts around the lamp will be very hot and
may cause burns or injury.
Info
Make sure that you remove the lamp unit by
the handle. Do not touch the glass surface of
the lamp unit or the inside of the projector.
To avoid injury to yourself and damage to the
lamp, make sure you carefully follow the steps
below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
1
Press
jector or
mote control to put the projector
into standby mode.
Wait until the cooling fan stops.
2
Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
3
Remove the lamp unit cover.
Turn the projector over. Loosen the user
service screw (ı ) that secures the lamp
unit cover. Remove the lamp unit cover
(ˇ ).
2
STANDBY/ON on the pro-
STANDBY on the re-
1
Optional
accessory
STANDBY/ON button
AC socket
1
2
1 – 9
Lamp unit
AN-XR10L2
User service scr ew
(for lamp unit cover)