[K] ADU entrance sensor
(1)
Take off the ADU cover
(
P.15-12 "[E] ADU cover").
(2)
Disconnect 1 connector. Release the latches
and take off the ADU entrance sensor.
[L] ADU exit sensor
(1)
Take off the ADU cover
(
P.15-12 "[E] ADU cover").
(2)
Take off the sheet.
(3)
Disconnect 1 connector. Release the latches
and take off the ADU exit sensor.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
AUTOMATIC DUPLEXING UNIT (ADU) (OPTION: MD-0102)
ADU entrance sensor
ADU exit sensor