Page 1
Teléfonos inalámbricos Contenido y precauciones de seguridad Controles de operación FT-8989 Procedimientos de alineamiento Diagrama a bloques Diagramas esquemáticos Procedimiento de localización de fallas Carta de voltajes de transistores y de IC Identificación de terminales de semiconductores Localización de partes eléctricas Diagramas de conexiones (alambrado) Vistas explotadas y lista de partes mecánicas...
Page 2
FILE NO. 2B0-9905 SERVICE MANUAL CORDLESS TELEPHONE FT-8989 PUBLISHED IN JAPAN, Sep., 1999...
ALIGNMENT PROCEDURE Test Mode For Base Unit Press the “PAGE” key about 3.0 seconds while turning the power on. 1. To change the TEST mode: Press the “PAGE” key with T/P switch to PULSE position. 2. To change channel: Press the “PAGE” key with T/P switch to TONE position. If changing the step, the channel returns to the start channel.
Page 6
Test Mode For Handset Unit To Perform the TEST mode, turn the power ON by pressing the “ ” and “#” buttons at the same time. When entered the TEST mode, the bell rings and the unit enters TEST mode 1. (Refer to the follwing table.) 1.
Page 7
Base Unit Transmitter Section BASE Unit AF GEN. Test Point Power Connections Meter DC IN TEL Line 1kHz 77.5mV 9V Jack Jack Test Point Frequency Counter AC 120V Adapter 60Hz Deviation Mater Preset Place the Base Unit in VCO/TX FREQ.ADJ mode in accordance with the procedure on page 3. Alignment Procedure step Adjustment...
Page 8
Receiver Section Connections BASE Unit AC Voltmeter RF SG Dummy Load (600-ohm) TEL Line Test Point Jack DC Voltmeter DC IN 9V Jack Terminal AC 120V 60Hz Adapter Preset Place the Base Unit in RX SENS mode (step 4) in accordance with the precedure on page 3. Alignment Procedure step Preset to...
Page 9
Handset Unit Transmitter Section Connection HANDSET Unit AF GEN. Test Point Power Meter J603 Battery 1kHz 9mV MIC+Pin Connector Test Point Frequency Counter DC Power Supply Deviation Mater DC 3.8V Preset Place the Handset in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 4. Alignment Procedure step Adjustment...
Page 10
Receiver Section Connections HANDSET Unit AC Voltmeter RF SG Dummy Load (150-ohm) Test Point Connector DC Power Supply J603 DC Voltmeter Battery Terminal Connector DC 3.8V Preset Place the Handset in RX SENS mode (step 4) in accordance with the procedure on page 4. Alignment Procedure step Preset to...
TROUBLESHOOTING HINTS 1. The bell does not ring. See 2. The bell does not ring When the PAGE SW of the & page does not ring. base is pressed, does the ringer on the handset ring? When the TEL SG is joined Check IC1 and TEL network with the base to make bell circuit.
Page 18
2. The bell does not ring & page does not ring. Can the base and handset be See 3. The base and handset connected? cannot be connected. Press handset DIAL key When the key of the handset is Check IC603. while in TALK MODE.
Page 19
3. The base and handset cannot be connected. Check whether the base Check IC6 and its is able to set in the test peripheral circuit. mode 1. Check the TX POWER Check base RF unit. and the TX FREQUENCY on the base unit. Set the base in the test Check whether there is a Check RT3, R51, R52,...
Page 20
Press “3” key, check Check whether there is a C h e c k R 6 3 5 , R 6 3 6 , whether deviation of the 250 Hz data waveform at R 6 3 4 , R 6 3 2 , R 6 1 9 , TX data is app.
Page 21
4. Cannot make a phone call (pulse). Can the base and handset See 3. The base and handset be connected? cannot be connected. While in TALK MODE, press Check IC6. dial key of the handset. Check whether square waveform from pin 23 of IC6 is fed.
Page 22
6. Voice cannot be transmitted to other party (outgoing call). Can the base and handset be See 3. The base and handset connected? cannot be connected. The 1 kHz, 9.0mV sine Check Q604 and its wavefor m i s a p p l i e d t o peripheral circuit.
Page 23
7. The voice of the caller cannot be heard (incoming call). Can the base and handset be See 3. The base and handset connected? cannot be connected. The 1 kHz, 77.5mV sine Check the base TEL-line waveform is applied to TEL- circuit and REPLAY control line of the base, can the 1 kHz circuit.
Page 26
Unit[V] Unit[V] Ref. No. PIN STBY TALK NOTE Ref. No. PIN STBY TALK NOTE OPEN OPEN OPEN OPEN OPEN IC202 IC202 3.6(AC) 3.6(AC) OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN...
Page 27
Unit[V] Unit[V] Ref. No. PIN STBY TALK NOTE Ref. No. PIN STBY TALK NOTE IC202 OPEN OPEN OPEN IC208 OPEN OPEN OPEN OPEN OPEN OPEN OPEN IC204 OPEN 3.6(AC) 3.6(AC) OPEN 3.1(AC) 3.1(AC) 3.1(AC) 3.1(AC) IC207 OPEN 1.33.29 OPEN OPEN IC208 OPEN OPEN...
PARTS LIST PRODUCT SAFETY NOTE : Products marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice of this service manual. Don’t degrade the safety of the product through important servicing. Symbol Symbol ±...
Page 44
LOC. REF. PART NO. DESCRIPTION RC008270 BCML811235Z CERAMIC M/L (1608) TAPE 0.012UF 50V K B RC008318 BCML815625Z CERAMIC M/L (1608) TAPE 0.0056UF 50V K B RC001809 BCAZ814786Z ELECTROLYTIC 0.47UF 50V M C-156 RC005205 BCML811035Z CERAMIC M/L (1608) TAPE 0.01UF 50V K B RC005202 BCML311045Z CERAMIC M/L (1608) TAPE...
Page 45
LOC. REF. PART NO. DESCRIPTION RC005205 BCML811035Z CERAMIC M/L (1608) TAPE 0.01UF 50V K B RC008548 BCEQ902216Z ELECTROLYTIC 220UF 6.3V M C-125 RC008731 BCXK311050Z CERAMIC M/L (2125) TAPE 1UF 16V Z F RC005204 BCML811025Z CERAMIC M/L (1608) TAPE 0.001UF 50V K B RC005215 BCMM812704Z CERAMIC M/L (1608) TAPE...
Page 46
LOC. REF. PART NO. DESCRIPTION C140 RC001802 BCAZ314706Z ELECTROLYTIC 47UF 16V M C-156 C142 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C143 RC005205 BCML811035Z CERAMIC M/L (1608) TAPE 0.01UF 50V K B C203 RC001811 BCAZ901016Z ELECTROLYTIC 100UF 6.3V M C-156 C205 RC008146 BCML816825Z...
Page 47
LOC. REF. PART NO. DESCRIPTION C251 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C252 RC008884 BCAZ904716Z ELECTROLYTIC 470UF 6.3V M C-156 C253 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C600 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C601 RC004347...
100X100X0.1T RC008423 VNYL3102500 VINYL BAG 100X250X0.1T ASSEMBLY PARTS LIST NOTE: Following part numbers are not available as replacement parts. Order parts necessary for repair or contact the Toshiba Factory Service Center. LOC. REF. PART NO. DESCRIPTION RC008508 AC222ZLBA MAIN PCB ASSEMBLY, BASE...