Page 1
AE242FCAKA 0010573331 Please read this manual carefully before use. Please keep it attentively for future use. H-MRV Ceiling Concealed Type Room Air Conditioner AE072FCAKA AE122FCAKA AE092FCAKA AE142FCAKA Contents Before Application Cautions Part Description Important Points of Safety Operating Instructions AUTO,COOL, DRY,HEAT Operation...
Page 3
Cautions Rated Maximum Minimum DB C Indoor WB C Cooling DB C outdoor WB C DB C Indoor Heating 14.5 WB C outdoor DB C WB C...
Page 4
AE072FCAKA AE242FCAKA AE092FCAKA , AE122FCAKA , AE142FCAKA , AE182FCAKA , AE212FCAKA have the Return air box (see the following picture) when shipping from the factory and they are back-side return air. During the installation, also can be changed to Down-side Return air according to the user's need.
Page 5
Use remote controller control the remote control window of the remote control receiver. Left picture is a wired remote controller, which can be used on AE072FCAKA(wired control), AE092FCAKA (wired control), AE122FCAKA(wired control), AE142FCAKA(wired control),AE182FCAKA(wired control),AE212FCAKA(wired control), AE242FCAKA (wired control). The remote controller can be purchased extrally.
Page 6
14 15 16 17 18 AUTO 1.ON/OFF button Used to turn on/off unit 2.Temperature display 3.Clock display 4.Timer ON/OFF display 5.Humidity display 6.Air filter cleaning display When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet.
Page 7
Remote LCD display contents and key name and each key function introduction T E M P SWING MODE SLEEP HEALTH FRESH CLOCK TIMER LIGHT LOCK RESET SWING MODE AUTO TEMP HEALTH CLOCK TIMER SLEEP ROOM FILTER RESET RESET ON/OFF Remote controller (Operation of remote controller) Make sure that the remote controller is used within 7 meters from receiver window of the wire controller and there are no obstructions in between.
Page 8
Remote LCD display contents and key name and each key function introduction 1.ON/OFF button 2.Temperature Setting button AUTO 3.Health T E M P HEALTH 4.Operation mode button MODE SWING TIMER 5.Timer button LOCK RESET CODE 6.Reset button 7.Fan speed button 8.Swing button 9.Time Adjusting button 10.Lock button...
Clock set When unit is started for the first time, clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Press to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM"...
Important Points of Safety The following four important points of safety and suggestions should be paid great attention: Warning: Misuse may cause fatal result such as death or serious injury etc. Attention: Misuse may cause human injury or damage of machine, in some case fatal results.
Page 11
Important Points of Safety Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. Donít extend your fingers or any other article into the inlet or outlet during operation of the machine for touching re- volving fans may cause human injury or damage of machine.
Page 12
Important Points of Safety * Ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. * Check whether installation bench of the machine is damaged after a long period of use. Machine on damaged bench may fall down and cause human injury or other damage.
Operating Instructions Recommendations Use COOL in summer. Use HEAT in winter. Use DRY in spring,autumn and in damp climate. MODE AUTO TEMP CLOCK TIMER FILTER RESET ON/OFF (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display (Not Timer setting).
Operating Instructions MODE TEMP HEALTH CLOCK TIMER FILTER RESET ON/OFF Set Clock correctly before starting Timer operation. You can let unit start or stop automatically at following time: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
Operating Instructions MODE TEMP HEALTH CLOCK TIMER FILTER RESET ON/OFF TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator lights up. (2) Press TIMER button to change TIMER mode Every time the button is pressed, display changes as follows: Select (3)Time setting for TIMER ON Press TIME button.
Operating Instructions Note: Before using this function, must adjust the clock, or the sleep function will be disordered. Comfortable Sleep At night, before going to bed you can press down the SLEEP button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.
Operating Instructions MODE SWING TEMP HEALTH CLOCK TIMER SLEEP FILTER RESET RESET ON/OFF On the "Health" mode, if you want to setting timing open mode, should close the health first: On the timing open mode, please don't use health function. Power Failure Compensation (to be applied for a necessary situation) : After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working, it will resume the previous working state when the power is supplied again.
Trouble Shooting The following cases are not troubles. Water flow sound is heard. "Hua-Hua" A sound of "Pi-Pa" is generated. Smells are given off. During operation, mist or steam are blown out. During COOL operation, it automatically changes to FAN mode. The system couldnt be re-started immediately after turning off.The unit can't start? During operation, the air conditioner may...
Page 19
Trouble Shooting During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode, the outdoor unit generates water or steam. In HEAT mode, the indoor fan still keeps running even the unit operation stops.
When Fault Occurs Poor cooling or heating Is the operation controller Are there any obstructs adjusted as required? before the air inlet or outlet? Is there any other heat Is there any direct sunlight source in the room? into the room? If, after the above checks and the corresponding corrective actions, the system remains abnormal operation, or the following facts appear, please turn off the air conditioner and then contact the local authorized service center.
Notice to Users Notice to users To ensure proper operation of the system, the user shall follow this instruction manual to install the unit. When handling the air conditioner, please be care not to scratch the case surface. This instruction manual describes the installation method aided with the installation tools specified by manufacturer .
Installation Precautions Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" Warning" " and " Note" two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will happen.
Installation Precautions This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd. This instruction manual must be read carefully before beginning of installation, improper ins- tallation may cause accidents and thus bring about machine damage and personal casualty.
4. Support the unit firmly. 5. Change the form of the connection pipe, connection wire and drain pipe so that they can go through the wall hole easily. Figure showing installation dimensions: (unit:mm) Model AE092FCAKA AE122FCAKA AE142FCAKA AE182FCAKA 1024 AE212FCAKA Notes 1.For electrical heating unit, the air outlet not allowed directly connecting with canvas...
Installation Procedure When installing the ceiling concealed type indoor unit, a specially designed return air bellows shall be installed, as shown in Figure 3, Figure 4. Figure 3 Installing building roof Ceiling Air supply Figure 4 Air outlet grille Air supply No obstacles within 1 m Each air return and supply duct should fix to the floor precast slab by using an iron stand.
Page 26
Installation Procedure Installation for air duct of indoor unit 1. Installation for air supply duct This type of unit uses circular air duct with its caliber of 180mm. An additional transitive air duct is necessary for the circular air duct to connect to the air supply inlet.
Page 27
Installation Procedure Installing the suspension screw: Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original building structures.
Installation Procedure 1. Remove upper cover of wire controller Remove upper part of wire controller by press. PCB is mounted on lower part of wire controller, be careful not to damage it. 2. Install the wired remote controller Please drill two holes on the wall according to the back cover screw hole position of the wire remote controller, then strike the wood block to the holes respectively, then align the 2 screw hole of the wire...
Page 29
Installation Procedure Installation of receive display Because of the temperature sensitive device, do not install the receive display at straight sunlight place, either in front of air outlet grill, for it is effected greatly from cool air and heat air, the receive display is at least 20mm distance to the air outlet grill. Since there is light sensitive device which receives wireless remote signal, so do not installed behind the window curtain or other obstacles, in order not to obstruct the signal.
Installation Procedure In order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements The indoor drain pipe shall be thermal insulated. The connection part between the drain pipe and the indoor unit shall be insulated so as to prevent dew generation.
Page 32
Installation Procedure Vacuum pumping With a vacuum pump, create vacuum from the stop valve of the outdoor unit. l Emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves Open all the valves on the outdoor unit. Gas leakage detection Check with a leakage detector or soap water that if there is gas leakage at the pipe connections and bonnets.
Installation Procedure The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. During wiring connection, the power cord shall be of the specified cable and reliably fastened so that external forces applied to the cable wouldnt transfer to the terminals.
Installation Procedure Wire connection for built-in indoor unit Insert from outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged. Pull out the front ends of connection wire and signal wire and make a circle on the signal wire.
Page 35
Malfunction Indoor unit malfunction display code Indoor unit malfunction Float switch or water motor abnormal Outdoor unit abnormal Setting running mode is different with outdoor running mode Liquid temperature sensor is abnormal Gas temperature sensor is abnormal The communication between indoor 846 chip and communication chip is abnormal The communication with electronic expansion box is abnormal...
Page 36
Malfunction Remote controller Timer and Operation indicator malfunction code When the unit running, Timer indicator flash stand for indoor unit malfunction operation indicator flashing stand for outdoor unit malfunction 1. Indoor unit malfunction Timer indicator Indoor unit malfunction Flashing times Flashing once The liquid tube temperature sensor is abnormal Flashing twice...